Seite 2, Oil leak stop – SCT-Germany OIL LEAK-STOP User Manual

Page 2

Advertising
background image

Prepared according to Annex II of EC Regulation 1907/2006

Printing Date: 12.12.2010

Revision Date: 12.12.2010

Page 2/5

Oil Leak Stop

05.

Fire-fighting measures

5.1 Suitable extinguishing media
CO2
Foam
Dry extinguisher
Cool container at risk with water.
5.2 Extinguishing media which shall not be used for safety reasons
High volume water jet
5.3 Special exposure hazards arising from the substance or preparation itself, combustion products,
resulting gases
In case of fire the following can develop:
Oxides of carbon, Hydrocarbons, Toxic pyrolysis products,Hot product gives off combustible vapours.
5.4 Special protective equipment for fire-fighters
In case of fire and/or explosion do not breathe fumes. Protective respirator with independent air supply.
According to size of fire Full protection, if necessary
5.5 Further information
Dispose of contaminated extinction water according to official regulations.

06. Accidental release measures

Refer to point 13. and for personal protection refer to point 8.
6.1 Personal precautions
Ensure sufficient supply of air. Remove possible causes of ignition - do not smoke. Avoid formation of oil mist.
Avoid contact with eyes or skin. If applicable, caution - risk of slipping
6.2 Environmental precautions
If leakage occurs, dam up. Prevent from entering drainage system. Prevent surface and ground-water infiltration,
as well as ground penetration. If accidental entry into drainage system occurs, inform responsible authorities.
6.3 Methods for cleaning up
Collect using absorbant material (e.g. Universal binding medium), and dispose of according to point 13.

07.

Handling and storage

7.1 Handling

Tips for safe handling:
See point 6.1
Ensure good ventilation. Do not heat to temperatures close to flash point. Eating, drinking, smoking, as well as
food-storage, is prohibited in work-room. Do not carry cleaning cloths soaked in product in trouser pockets.
Observe directions on label and instructions for use.

7.2. Storage

Requirements for storage rooms and containers:
Not to be stored in gangways or stair wells. Store product closed and only in original packing. Solvent resistant
floor Do not store with oxidizing agents.
Special storage conditions:
See point 10
Protect from direct sunlight and warming.

08.

Exposure controls/personal protection

Chemical Name

content%: 1-10

WEL-STEL: 50 ppm (333 mg/m³) (WEL, EC)

Chemical Name

content%:

WEL-STEL: 10 mg/m³ (ACGIH)

Chemical Name

content%:

WEL-STEL: 2 (II) (AGW)

Baseoil - unspecified

---

BMGV: ---

Other informations: ---

WEL-TWA: 300 mg/m³ (AGW)

Oil mist, mineral

WEL-TWA: 5 mg/m³ (ACGIH)

---

BMGV: ---

Other informations: Sk (WEL)

Other informations: ---

WEL-TWA: 20 ppm (133 mg/m³) (WEL, EC)

---

2-Butoxyethyl acetate

BMGV: ---

WEL-TWA = Workplace Exposure Limit - Long-term exposure limit (8-hour TWA (= time weighted average) reference period) EH40. AGW =
"Arbeitsplatzgrenzwert" (workplace limit value, Germany). | WEL-STEL =Workplace Exposure Limit - Short-terme exposure limit (15-minute
reference period). | BMGV = Biological monitoring guidance value EH40. BGW = "Biologischer Grenzwert" (biological limit value, Germany) |
Other information: Sen = Capable of causing occupational asthma. Sk = Can be absorbed through skin. Carc = Capable of causing cancer
and/or heritable genetic damage. ** = The exposure limit for this substance is repealed through the TRGS 900 (Germany) of January 2006 with
the goal of revision.

Advertising