Mounting

Vertical mounting on a wall or heavy pillar is preferred for

most wrench and tool testing as shown in the illustration

below. Use four 1/4” diameter bolts (torqued to 10 FT LB)

to insure a secure mount. The DTT can also be mounted

vertically to a horizontal surface using a right angle

bracket.

A – Mounting Screw (4)
B – Right Angle Bracket

10

DTT Digital Torque Tester

Figure 3: Mounting, Dimensions and Right Angle Bracket

A

B

8.87”

8.87”

2503-F-DTT

25 - 250 FT.LB.

Mount the DTT to a sturdy support before use. Torque

testing procedures may involve hundreds of pounds of

load. Be sure to consider counterweight of the mount to

accommodate torque testing operations and testing

fixtures. Allow enough room around and below the mount

for the wrenches or testing fixtures being used.