DTT Digital Torque Tester

6b. Press the CHANGE button next to WRENCH SIZE to

enter the Full Scale torque and Units of the wrench

being calibrated (Figure 14).

NOTE: If the incorrect value is entered, press BS to

clear the last digit entered, or press CLEAR to

delete the entire entry.

Press UNITS to scroll between FT-LB, IN-LB,

IN-OZ, KG-CM, Nm and cNm units.

Press NEXT to accept the entry and return to the

TEST SETUP screen.

NOTE: For information on how to update

SERIAL NUM, and

OPERATOR ID;

please refer to Steps 5c & 5d.

Press TEST to accept all entries.

ENTER WRENCH MAX RANGE :

MAIN

CLEAR

NEXT

UNITS

Figure 14: Wrench Max Range screen

FT-LB

250

1

2

3

4

5

6

7

8

9

0