Dual peak feature, Max peak feature, No peak features – Speedhut 2-1_16 inch, 2-5_8 inch, & 3-3_8 inch Revolution_Legacy Gauge User Manual

Page 2

Advertising
background image

Setting warning LED for both low and high.

LED can be set to turn on for both a low or high condition, or

To reset LED set point at any time follow this procedure again.

1. To enter LED calibration mode, Press and hold LED button

2-1/16" LED button

LED

High

set

LED turns on

above the set point.

Low

set

LED turns on

below the set point.

warning light

right side only

2-5/8" and 3-3/8” gauges

Peak recall memory (Revolution line only)

Press and hold gauge button down and gauge needle will move between low and high peak. Gauge will continue toggling between low and high peaks as long

as button is pressed.

Note: low peak becomes active once gauge needle travels up at least 1/8 scale initially. Once this condition occurs low peak becomes active and will record the

lowest reading the gauge achieves.

To retain peak reading (NOT CLEAR IT)

While showing peak reading, release button, wait 5 seconds, gauge will return to normal and retain the peak reading.

To clear peak reading

d pointer will travel to zero to

indicate peak has been cleared

----------------------------Note: For Revolution Series gauges with setable warning light see below----------------------------

--------------------------

Dual Peak Feature

Boost

Pressure
Air Fuel

Max Peak Feature

Temperature

EGT
Voltage

NO Peak Features

Fuel level

Vacuum

WARRANTY - Speedhut inc. warrants to the consumer for a period of 5 years from the date of purchase that the product will be free from defects in materials or workmanship.

Speedhut warrants to the consumer for a "LIFE-TIME" that the gauge circuit board will be free from defects in materials or workmanship. Please contact Speedhut service dept.

If you have a problem with this gauge. [email protected]

Note: for 2-5/8" gauges plug button into the left jack on the back of the gauge.

Gauge top

Setting LED brightness both day and night.

2. Pointer will slowly scan clock-wise from min. low condition on dial.

Press button at desired low warning set point. LED will blink to indicate

low warning point has been set. Note: Pressing button at min. low

(6 o'clock position) on dial will turn off low LED warning so that

it does not light up.

Note: Setting a low warning will turn on LED when pointer travels

below the low set point. Setting a high warning will turn on LED

above the high set point.

3. Pointer will now travel to full high condition on dial and

slowly scan counterclockwise. Press button at desired set point

for high condition. LED will blink to indicate high warning has

been set. Note: Pressing button at max high position on the

dial will turn off high LED warning so that it does not light up.

1. With gauge power on press and release LED button (LED will light up at current brightness setting).

2. Press and release LED button to change LED to desired brightness setting.

Note: 5 Settings options - off, 1, 2, 3, 4 (4 is the the brightest.)

3. Do not press the button for three seconds to save the brightness setting. The LED will blink to indicate that setting has been saved.

Note: Setting the brightness setting when the gauge lighting is on, will set the night-time brightness setting. Setting the level when the gauge

lighting is off will set the daytime brightness setting.

Note: 2-5/8" and 3-3/8"

gauges plug button in back

of gauge on left side only.

Advertising