SOARER TT BLOW-OFF VALVE ADAPTOR INSTRUCTIONS

Head Office: Turbosmart Pty Limited, PO Box 264 Croydon, NSW, 2132 Australia

Ph: +61(2) 9798 2866

Fax: +61 (2) 9798 2826

Email:

[email protected]

USA Office: Turbosmart USA, 1185 Park Center Drive, Suite Q, Vista CA 92081 USA

Ph: (760) 727 7610

Fax: (760) 727 7963

Email:

[email protected]

PART NUMBER
FG-ADM-SOARER



Step 9. Remove the factory BOV.

Step 10. Take the O ring from the factory BOV and fit
it over the Soarer BOV blank supplied. Install the blank
over the pipe flange and secure it with the original
factory nut.


Step 11.
Block off the factory return hose with the
29mm blanking plug supplied. Use the supplied 40mm
hose clamp to secure the plug. Then tighten, using a
7mm socket.

Step 12. Replace the factory return pipe on its
original fitting and secure it with a 40mm hose clamp
supplied. Tighten the clamp with a 7mm socket.


Step 13. Connect the pre-assembled silicon hose
assembly as shown in the diagram below:

Step 14. Install one end of the Silicon hose assembly
supplied onto the metal tube and secure with the 6mm
spring clamp supplied.

BOV

Blank

Pipe flange

Connect end to
throttle body

Connect other end
to Turbosmart BOV

1700mm

Advertising