Main page input – TC Electronic Finalizer 96k User Manual

Page 15

Advertising
background image

15

MAIN PAGE

Input

Sample Rate Conversion may be applied to the AES/EBU,

S/PDIF or Tos-link Input. The Input Sample rate is asynchronous,

with the Output of the Sample Rate Converter locked to the

system Clock source.

Internal references at 44.1and 48 or an external Word Clock

signal may be used to drive the Sample Rate Converter.

Sample Rate LEDs

When a Digital Input is used, and the signal is recognized, one of

the three yellow Rate LEDs light up. If no signal is present, and

you’ve selected a Digital Input or Insert, all three LEDs will blink.

Note: Blinking LEDs indicate an error condition. The Outputs of

the Finalizer are muted.

Digital Input Formats and levels

Several Digital Input formats are supported: AES/EBU, S/PDIF,

Tos-link and ADAT. If you select ADAT format, you are allowed

to pick two independent tracks for processing in the Finalizer.

Format conversions between any of the mentioned formats are

available.

Level calibrations are easily maintained in the Digital domain.

However, with a Digital Input selected, level and balance

adjustments may be performed digitally in Input page 2.

When a Digital Input is selected, the Clock selection defaults to

EXT DI (External Digital In). This selection may be overruled as

explained in the ”Sample Rate”.

Mode 48/96

Mode 48 gives you a maximum frequency response of 24kHz.

Mode 96* (Double Sample Rate) gives you a maximum

frequency response of 48kHz.

Unlimited Up and Down Sampling

Sample Rate Conversion between all Sample Rates is possible.

Input Sample Rates of 44.1, 48, 88.2 or 96kHz is accepted and

can be up/down-sampled to 44.1, 48, 88.2 or 96kHz.

This up and down sampling feature is available from software

version 3.50 and up and requires a minor hardware upgrade.

Please contact your local dealer for further information regarding

upgrade procedure and upgrade fee.

The new hardware is installed from factory in Finalizer 96K’s

with serial no. 1214250 and above. To see if the new hardware is

installed: Install the 3.5 software and reboot the unit. If the

Up/Down sampling logo appears during power-up, both software

and hardware is installed

Note: Software 3.5 will operate on Finalizer PLUS and old Finalizer

96K, but the up/downsampling feature is available only in

conjunction with the hardware update.

Example 1:

You have a Digital signal at a Sample Rate of 96kHz present on

the Input and you wish to have a signal at a Sample Rate of

44.1kHz on the Output.

- Select Digital Input type: S/PDIF, AES/EBU or Tos.

- Set the Sample Rate Conversion SRC to “On”.

- Select “Mode48”.

- Select Output Clock frequence 44.1kHz.

You now have a Clock Rate on the Output of 44.1kHz

Example 2:

You have a Digital signal at a Sample Rate of 44.1kHz present

on the Input and you wish to have a signal at a Sample Rate of

96kHz on the Output.

- Select Digital Input type: S/PDIF, AES/EBU or Tos.

- Set the Sample Rate Conversion SRC to “On”.

- Select “Mode96”.

- Select Output Clock frequence 96kHz.

You now have a Clock Rate on the Output of 96kHz

Example 3:

You have an Analog signal on the Input and you wish to have a

signal at a Sample Rate of 96kHz on the Output.

- Select Input type: Analog.

- Sample Rate Conversion is automatically set to “Off”.

- Select Mode 96.

- Select Output Clock frequence 96kHz.

You now have a Clock Rate on the Output of 96kHz.

Clock - Sample Rate

Select which clock you want the Finalizer to sync to.

Mode 48: Internal 44,1, Internal 48, External sync. or External

Sync, AES/EBU, S/PDIF or ADAT.

Mode 96*: Internal 88,2, Internal 96, External sync. or External

Sync, AES/EBU, S/PDIF or ADAT.

Optical - Digital Output Formats

The available Output formats are determined by the Input and

Insert selections. Optical Outputs may be chosen between ADAT,

Tos-link and Thru.

- When ADAT is selected, you may assign the Finalizer

signals to any two ADAT channels.

- When Thru is selected, the Optical Output is a copy of the

Optical Input, regardless of format.

* 96kHz is only available in Finalizer 96. “MODE 96” must be

selected.

Advertising