Table 2. threshold suffix guide, Table 3. watchdog timeout – Rainbow Electronics MAX6869 User Manual

Page 13

Advertising
background image

input at different points in the program, rather than
pulsing the watchdog input high-low-high or low-high-
low. This technique avoids a stuck loop, in which the
watchdog timer would continue to be reset inside the
loop, keeping the watchdog from timing out.

Figure

6 shows an example of a flow diagram where

the I/O driving the watchdog input is set high at the
beginning of the program, set low at the beginning of
every subroutine or loop, then set high again when the
program returns to the beginning. If the program
should hang in any subroutine, the problem would
quickly be corrected, since the I/O is continually set low
and the watchdog timer is allowed to time out, causing
a reset or interrupt to be issued.

MAX6854–MAX6869

Nanopower µP Supervisory Circuits with

Optional Manual Reset, Watchdog Timer

______________________________________________________________________________________

13

START

SET WDI

HIGH

PROGRAM

CODE

SUBROUTINE OR
PROGRAM LOOP

SET WDI LOW

RETURN

V

CC

THRESHOLD FALLING

SUFFIX

MIN

TYP

MAX

UNITS

46

4.509

4.625

4.741

45

4.388

4.500

4.613

44

4.266

4.375

4.484

43

4.193

4.300

4.408

42

4.095

4.200

4.305

41

3.998

4.100

4.203

40

3.900

4.000

4.100

39

3.802

3.900

3.998

38

3.705

3.800

3.895

37

3.608

3.700

3.793

36

3.510

3.600

3.690

35

3.413

3.500

3.588

34

3.315

3.400

3.485

33

3.218

3.300

3.383

32

3.120

3.200

3.280

31

2.998

3.075

3.152

30

2.925

3.000

3.075

29

2.852

2.925

2.998

28

2.730

2.800

2.870

27

2.633

2.700

2.768

26

2.559

2.625

2.691

25

2.438

2.500

2.563

24

2.340

2.400

2.460

23

2.255

2.313

2.371

225

2.180

2.235

2.290

22

2.133

2.188

2.243

21

2.048

2.100

2.153

20

1.950

2.000

2.050

19

1.853

1.900

1.948

18

1.755

1.800

1.845

17

1.623

1.665

1.707

16

1.536

1.575

1.614

V

Figure

6. Watchdog Flow Diagram

Table

2. Threshold Suffix Guide

WATCHDOG TIMEOUT PERIOD

SUFFIX

MIN

TYP

MAX

UNITS

S

1.5

3.3

7.75

L

95

209

487

s

Table

3. Watchdog Timeout