Ordering information (continued), Table 4. reset timeout periods, Table 5. standard versions – Rainbow Electronics MAX6869 User Manual

Page 14

Advertising
background image

MAX6854–MAX6869

Nanopower µP Supervisory Circuits with
Optional Manual Reset, Watchdog Timer

14

______________________________________________________________________________________

RESET TIMEOUT PERIODS

TIMEOUT

OPTION

MIN

TYP

MAX

UNITS

D1

10

15

25

D2

40

60

80

D3

150

225

300

D4

1200

1800

2400

D5

300

450

600

D6

600

900

1200

ms

Table

4. Reset Timeout Periods

PART

TOP MARK

MAX6854UK16D3

AEFS

MAX6854UK23D3

AEFY

MAX6854UK26D3

AEFZ

MAX6854UK29D3

AEGA

MAX6854UK31D3

AEGB

MAX6856UK16D3

AEGR

MAX6856UK23D3

AEGS

MAX6856UK26D3

AEGT

MAX6856UK29D3

AEGU

MAX6856UK31D3

AEGV

MAX6861UK17

AEKO

MAX6861UK225

AEKS

MAX6861UK26

AEKP

MAX6861UK29

AEKQ

MAX6862UK17

AEOS

MAX6862UK225

AEOT

MAX6862UK26

AEOU

MAX6862UK29

AEOV

MAX6863UK17

AEOW

MAX6863UK225

AEOX

MAX6863UK26

AEOY

MAX6863UK29

AEOZ

MAX6864UK16D3S

AEGC

MAX6864UK23D3S

AEGD

MAX6864UK26D3S

AEGE

MAX6864UK29D3S

AEGF

MAX6864UK31D3S

AEGG

MAX6866UK16D3S

AEGW

MAX6866UK23D3S

AEGX

MAX6866UK26D3S

AEGY

MAX6866UK29D3S

AEFT

MAX6866UK31D3S

AEGZ

Table

5. Standard Versions

Ordering Information (continued)

PART

TEMP RANGE

PIN-PACKAGE

MAX6856

UK_ _D_-T*

-40°C to +85°C

5 SOT23-5

MAX6857

UK_ _D_-T*

-40°C to +85°C

5 SOT23-5

MAX6858

UK_ _D_-T*

-40°C to +85°C

5 SOT23-5

MAX6859

UK_ _D_-T*

-40°C to +85°C

5 SOT23-5

MAX6860

UK_ _D_-T*

-40°C to +85°C

5 SOT23-5

MAX6861

UK_ _-T

-40°C to +85°C

5 SOT23-5

MAX6862

UK_ _-T*

-40°C to +85°C

5 SOT23-5

MAX6863

UK_ _-T*

-40°C to +85°C

5 SOT23-5

MAX6864

UK_ _D_ _-T*

-40°C to +85°C

5 SOT23-5

MAX6865

UK_ _D_ _-T*

-40°C to +85°C

5 SOT23-5

MAX6866

UK_ _D_ _-T

-40°C to +85°C

5 SOT23-5

MAX6867

UK_ _D_ _-T*

-40°C to +85°C

5 SOT23-5

MAX6868

UK_ _D_ _-T*

-40°C to +85°C

5 SOT23-5

MAX6869

UK_ _D_ _-T*

-40°C to +85°C

5 SOT23-5

Insert reset threshold suffix (see Table 2, Threshold Suffix
Guide) after UK. Insert the number corresponding to the desired
reset timeout period (see Table 4, Reset Timeout Period) after
“D.” Insert the letter corresponding to the desired watchdog
timeout period (S or L, see Table 3) into the blank following the
reset timeout period suffix for the MAX6864–MAX6869.

Note: Sample stock is generally held on standard versions
only (see Table 5, Standard Versions Table). Standard versions
have an order increment of 2500 pieces. Nonstandard versions
have an order increment of 10,000 pieces. Contact factory for
availability of nonstandard versions.

*Future product—Contact factory for availability.

Advertising