Table 1. register functions (continued) – Rainbow Electronics MAX6641 User Manual

Page 7

Advertising
background image

MAX6641

SMBus-Compatible Temperature Monitor with

Automatic PWM Fan-Speed Controller

_______________________________________________________________________________________

7

READ/

WRITE

REGISTER

ADDRESS

POR

STATE

FUNCTION/

NAME

D7

D6

D5

D4

D3

D2

D1

D0

R/W

0Ch

0000 0000

Local-diode

fan-start

temperature

MSB

(+128

°C)

(+64

°C)

(+32

°C)

(+16

°C) (+8°C)

(+4

°C)

(+2

°C)

LSB

(+1

°C)

R/W

0Dh

0000 xxxx

Fan

configuration

H yster esi s:

0 = 5

°C ,

1 = 10

°C

Temp

step: 0 =

1

°C, 1 =

2

°C

Fan control:

1 = remote

Fan

control:

1 = local

X

X

X

X

R/W

0Eh

101x xxxx

Duty-cycle

rate of change

MSB

LSB

X

X

X

X

X

R/W

0Fh

0101 xxxx

Duty-cycle

step size

MSB

LSB

X

X

X

X

R/W

10h

010x xxxx

PWM

frequency

select

Select A

Select B

Select C

X

X

X

X

X

R

FDh

0000 0001

Read device

revision

0

0

0

0

0

0

0

1

R

FEh

1000 0111

Read

device ID

1

0

0

0

0

1

1

1

R

FFh

0100 1101

Read

manufacturer

ID

0

1

0

0

1

1

0

1

Table 1. Register Functions (continued)

X = Don’t care. See register descriptions for further details.