Rainbow Electronics MAX6641 User Manual

Page 8

Advertising
background image

MAX6641

SMBus-Compatible Temperature Monitor with
Automatic PWM Fan-Speed Controller

8

_______________________________________________________________________________________

Write Byte Format

Read Byte Format

Send Byte Format

Receive Byte Format

Slave address: equiva-
lent to chip-select line of
a 3-wire interface

Command byte: selects which
register you are writing to

Data byte: data goes into the register
set by the command byte (to set
thresholds, configuration masks, and
sampling rate)

Slave address: equivalent
to chip-select line

Command byte: selects
which register you are
reading from

Slave address: repeated
due to change in data-
flow direction

Data byte: reads from
the register set by the
command byte

Command byte: sends com-
mand with no data, usually
used for one-shot command

Data byte: reads data from
the register commanded
by the last read byte or
write byte transmission;
also used for SMBus alert
response return address

S = Start condition

Shaded = Slave transmission

P = Stop condition

/// = Not acknowledged

Figure 1. SMBus Protocols

S

ADDRESS

RD

ACK

DATA

///

P

7 bits

8 bits

WR

S

ACK

COMMAND

ACK

P

8 bits

ADDRESS

7 bits

P

1

ACK

DATA

8 bits

ACK

COMMAND

8 bits

ACK

WR

ADDRESS

7 bits

S

S

ADDRESS

WR

ACK

COMMAND

ACK

S

ADDRESS

7 bits

8 bits

7 bits

RD

ACK

DATA

8 bits

///

P

SMBCLK

A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE

A

B

C

D

E

F

G

H

I

J

SMBDATA

t

SU:STA

t

HD:STA

t

LOW

t

HIGH

t

SU:DAT

t

SU:STO

t

BUF

L

M

K

E = SLAVE PULLS SMBDATA LINE LOW
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO SLAVE
H = LSB OF DATA CLOCKED INTO SLAVE

I = MASTER PULLS DATA LINE LOW
J = ACKNOWLEDGE CLOCKED INTO SLAVE
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION
M = NEW START CONDITION

Figure 2. SMBus Write Timing Diagram