Preliminary W49L102

- 10 -

Command Codes for Boot Block Lockout Enable

BYTE SEQUENCE

BOOT BLOCK LOCKOUT FEATURE SET

ADDRESS

DATA

1 Write

5555H

AAH

2 Write

2AAAH

55H

3 Write

5555H

80H

4 Write

5555H

AAH

5 Write

2AAAH

55H

6 Write

5555H

40H

Pause 1 Sec.

Boot Block Lockout Enable Acquisition Flow

Boot Block Lockout

Feature Set Flow

Load data AA

to

address 5555

Load data 55

to

address 2AAA

Load data 80

to

address 5555

Load data AA

to

address 5555

Load data 55

to

address 2AAA

Load data 40

to

address 5555

Pause 1 Sec.

Exit

Notes for boot block lockout enable:
Data Format: DQ15-DQ8 Don't Care), DQ7

DQ0 (Hex)

Address Format: A14

A0 (Hex)