Command Codes for Product Identification and Boot Block Lockout Detection

BYTE

SEQUENCE

ALTERNATE PRODUCT (6)

IDENTIFICATION/BOOT BLOCK

LOCKOUT DETECTION ENTRY

SOFTWARE PRODUCT

IDENTIFICATION/BOOT BLOCK LOCKOUT

DETECTION EXIT (7)

ADDRESS

DATA

ADDRESS

DATA

1 Write

5555

AA

5555H

AAH

2 Write

2AAA

55

2AAAH

55H

3 Write

5555

90

5555H

F0H

Pause 20

µ

S

Pause 20

µ

S

Software Product Identification and Boot Block Lockout Detection Acquisition Flow

Product

Identification

Entry (1)

Load data 55

to

address 2AAA

Load data 90

to

address 5555

Pause 10 S

Product

Identification

and Boot Block
Lockout Detection

Mode (3)

Read address = 00000

data = DA

Read address = 00001

data = BF

Read address = 00002

data = FF/FE

(4)

Product

Identification Exit(7)

Load data 55

to

address 2AAA

Load data F0

to

address 5555

Normal Mode

(5)

(2)

(2)

Load data AA

to

address 5555

µ

Load data AA

to

address 5555

Pause 10 S

µ

Notes for software product identification/boot block lockout detection:
(1) Data Format: DQ15-DQ8 (Don't Care), DQ7

DQ0 (Hex); Address Format: A14

A0 (Hex)

(2) A1

A15 = V

IL

; manufacture code is read for A0 = V

IL

; device code is read for A0 = V

IH

.

(3) The device does not remain in identification and boot block lockout detection mode if power down.
(4) If the output data is "FF Hex," the boot block programming lockout feature is activated; if the output data "FE Hex," the

lockout feature is inactivated and the block can be programmed.

(5) The device returns to standard operation mode.
(6) Optional 1-write cycle (write F0 hex at XXXX address) can be used to exit the product identification/boot block lockout

detection.