MAX6791–MAX6796

High-Voltage, Micropower, Single/Dual Linear
Regulators with Supervisory Functions

18

______________________________________________________________________________________

Selecting Watchdog Timeout Period

The watchdog timeout period is adjustable to accommo-
date a variety of µP applications. With this feature, the
watchdog timeout can be optimized for software execu-
tion. The programmer can determine how often the
watchdog timer should be serviced. Adjust the watch-
dog timeout period (t

WD

) by connecting a capacitor

between CSWT and GND. For normal-mode operation,
calculate the watchdog timeout capacitor as follows:

where t

WD

is in seconds and C

CSWT

is in Farads.

To select the internally fixed watchdog timeout period
for the MAX6791–MAX6794, connect CSWT to OUT1.
To select the internally fixed watchdog timeout period
for the MAX6795/MAX6796, connect CSWT to OUT.
Driving CSWT low disables the watchdog timer.

C

CSWT

must be a low-leakage (< 10nA) type capacitor.

Ceramic capacitors are recommended; do not use
capacitors lower than 100pF to avoid the influence of
parasitic capacitances.

The MAX6791/MAX6792 have a windowed watchdog
timer that asserts RESET for t

RP

when the watchdog

recognizes a fast watchdog fault (time between transi-
tions < t

WD1

), or a slow watchdog fault (time between

transitions > t

WD2

). The reset timeout period is adjust-

ed independently of the watchdog timeout period. The
slow watchdog period, t

WD2

, is calculated as follows:

where t

WD2

is in seconds and C

CSWT

is in Farads.

The fast watchdog period, t

WD1

, is selectable as a ratio

from the slow watchdog fault period (t

WD2

). Select the

fast watchdog period by connecting WDS0 and WDS1 to
OUT/OUT1 or GND according to Table 4, which illus-
trates the settings for the 8, 16, and 64 window ratios
(t

WD2

/t

WD1

). For example, if C

CSWT

is 2000pF, and

WDS0 and WDS1 are low, then t

WD2

is 318ms (typ) and

t

WD1

is 40ms (typ). RESET asserts if the watchdog input

has two edges too close to each other (faster than t

WD1

);

or has edges that are too far apart (slower than t

WD2

).

All WDI inputs are ignored while RESET is asserted. The
watchdog timer begins to count after RESET is
deasserted. If the time difference between two transi-
tions on WDI is shorter than t

WD1

or longer than t

WD2

,

RESET is forced to assert low for the reset timeout peri-
od. If the time difference between two transitions on WDI
is between t

WD1

(min) and t

WD1

(max) or t

WD2

(min)

and t

WD2

(max), RESET is not guaranteed to assert or

deassert; see Figure 3. To guarantee that the window
watchdog does not assert RESET, strobe WDI between
t

WD1

(max) and t

WD2

(min). The watchdog timer is

cleared when RESET is asserted. Disable the watchdog
timer by connecting WDS0 high and WDS1 low.

There are several options available to disable the
watchdog timer (for system development or test pur-
poses or when the µP is in a low-power sleep mode).
One way to disable the watchdog timer is to drive
WD-DIS low for the MAX6793–MAX6796 and drive
WDS0 high and WDS1 low for the MAX6791/MAX6792.
Another method of disabling the watchdog timer is to
pull CSWT low with an open-drain driver stage. This
prevents the capacitor from ramping up. Finally, reduc-
ing the OUT/OUT1 regulator current below the speci-
fied regulator current watchdog-disable threshold (3mA
min) also disables the watchdog timer. The watchdog

t

C

V

A

WD

CSWT

2

6

155

10

=

×







t

C

V

A

WD

CSWT

2

6

155

10

=

×







t

WD1

t

WD2

t

WD0

MIN

GUARANTEED

TO ASSERT

UNDETERMINED

UNDETERMINED

GUARANTEED

TO NOT ASSERT

GUARANTEED

TO ASSERT

FAST
FAULT

NORMAL
OPERATION

SLOW
FAULT

RESET:

WDI INPUT:

MAX

MIN

MAX

Figure 3. Windowed Watchdog Timing Diagram