Use the following formulas to determine the high/low
threshold levels and the hysteresis:

V

L-H

= V

PFI

x (1 + R5 / R6 +R5 / R7)

V

H-L

= V

PFI

x (1 + R5 / R6 ) + (V

PFI

- V

TERM

) [R5 / (R7 +

R8)]

V

HYS

= V

PFI

x (R5 / R7 ) - (V

PFI

- V

TERM

) [R5 / (R7 +

R8)]

where V

L-H

is the threshold level for the monitored volt-

age rising and V

H-L

is the threshold level for the moni-

tored voltage falling.

Chip Information

PROCESS: BiCMOS

Table 2. Preset Timeout Period

PART

SUFFIX (_)

RESET TIMEOUT PERIOD

(NOMINAL)

D0

35µs

D1

3.125ms

D2

12.5ms

D3

50ms

D4

200ms

Table

1. Preset Output Voltage and Reset

Threshold

PART

SUFFIX (_)

OUTPUT

VOLTAGE (V)

RESET THRESHOLD

(NOMINAL)

L

5.0

4.625

M

5.0

4.375

T

3.3

3.053

S

3.3

2.888

Z

2.5

2.313

Y

2.5

2.188

W

1.8

1.665

V

1.8

1.575

OPERATING

STATE

ENABLE1/

ENABLE

HOLD

REGULATOR 1

OUTPUT

COMMENT

Initial state

Low

Don’t care

Off

ENABLE/ENABLE1 is pulled to GND through internal pulldown.
OUT/OUT1 is disabled.

Turn-on state

High

Don’t care

On

ENABLE/ENABLE1 is externally driven high turning OUT/OUT1
on. HOLD is pulled up to OUT/OUT1.

Hold setup state

High

Low

On

HOLD is externally pulled low while ENABLE/ENABLE1
remains high, and the regulator latches on.

Hold state

Low

Low

On

ENABLE/ENABLE1 is driven low (or allowed to float low by an
internal pulldown). HOLD remains externally pulled low
keeping OUT/OUT1 on.

Off state

Low

High (floats

high)

Off

HOLD i s d r i ven hi g h ( or al l ow ed to fl oat hi g h b y the i nter nal p ul l up )
w hi l e E N ABLE /E N ABLE 1 i s l ow . OUT/OUT1 i s tur ned off and
E N ABLE /E N ABLE 1 and HOLD l og i c r etur ns to the i ni ti al state.

Table

3. ENABLE/ENABLE1 and HOLD Truth

Table

/State

Table

Advertising