MAX7042

308MHz/315MHz/418MHz/433.92MHz

Low-Power, FSK Superheterodyne Receiver

_______________________________________________________________________________________

7

S11 SMITH PLOT OF R

FIN

MAX7042 toc19

433.92MHz

INPUT IMPEDANCE

vs. INDUCTIVE DEGENERATION

MAX7042 toc20

INDUCTIVE DEGENERATION (nH)

REAL IMPEDANCE (

)

10

30

40

50

60

70

20

IMAGINARY IMPEDANCE (

)

-190

-180

-170

-160

-150

-200

1

100

f

RF

= 315MHz

IMAGINARY

IMPEDANCE

REAL IMPEDANCE

INPUT IMPEDANCE

vs. INDUCTIVE DEGENERATION

MAX7042 toc21

INDUCTIVE DEGENERATION (nH)

REAL IMPEDANCE (

)

10

30

40

50

60

70

80

90

20

IMAGINARY IMPEDANCE (

)

-130

-120

-110

-100

-140

1

100

f

RF

= 433.92MHz

IMAGINARY

IMPEDANCE

REAL IMPEDANCE

-70

-130

100

10k

1k

100k

1M

10M

PHASE NOISE

vs. OFFSET FREQUENCY

-120

-110

-90

-100

-80

MAX7042 toc22

OFFSET FREQUENCY (Hz)

PHASE NOISE (dBc/Hz)

f

RF

= 315MHz

f

RF

= 433.92MHz

Typical Operating Characteristics (continued)

(Typical Application Circuit, V

DD

= 3.0V, f

RF

= 433.92MHz, IF BW = 280kHz, data rate = 4kbps Manchester encoded, frequency

deviation = ±50kHz, BER = 0.2%, T