Outline drawing, Ordering code, Th7834c – Rainbow Electronics TH7834C User Manual

Page 12

Advertising
background image

12

TH7834C

1997A–IMAGE–05/02

Figure 8. Timing Diagram For Exposure Time Control

Note:

It is better to have

Φ

A

falling/rising edge outside the useful readout period.

Outline Drawing

Note:

Antireflective window: reflection.
Less than 1% per side over 400 - 700 nm wavelength range.
All dimensions are in mm (except otherwise specified).

Ordering Code

The ordering code is TH7834CCC-RB

Table 7. Exposure Time Reduction Conditions

Parameter

Symbol

Value

Unit

Min.

Typ.

Max.

Antiblooming Diode Bias

VA

1-2

. VA

3-4

14

15.5

15

V

Antiblooming And Expose Time
Control

Period 1

Φ

A1-2

,

Φ

A3-4

to be adjusted

V

Period 2

9.5

10

10.5

V

Φ

P(1-2, 3,4)

Φ

A(1-2, 3,4)

Antiblooming
level

0V

Period 2

Clear period

Period 1

t

20ns

TR

TR = Readout period

integration time ti

2.54

±

0

.25

1.27

±

0

.25

7.50

±

0

.10

3.2

4.2

4.35

±

0

.45

88.0 ±0.88.

5.00

0.10

±

Y

X

1st pixel

pixel 12000
|Y12000-Y1|

≤ 150 µ

m

15.24 ±0.25

Z=1.80±0.30

1.10

±

0

.10

3.

15

±0

.32

2.12

±

0.2

7

68.58

0.25

(2.54

±

× 27)

9.71

0.6

±

PIXEL 1 MARK

2

3

1

1

2

3

Window

Photosensitive area

Optical distance between
external face of window
and photosensitive area

Advertising