Operating precautions, Operating conditions (t = 25˚c), Timing diagram – Rainbow Electronics TH7834C User Manual

Page 6: Th7834c, Operating conditions (t = 25°c)

Advertising
background image

6

TH7834C

1997A–IMAGE–05/02

Operating
Precautions

Shorting the video outputs to VSS or VDD, even temporarily, can permanently damage
the output amplifiers.

Operating Conditions (T = 25°C)

Note:

If no exposure time control is required,

Φ

A1-2

and

Φ

A3-4

must be connected to an adjustable DC bias (see Figure 7).

Typical current in V

DR

, V

A

< 10 µA; in V

GS

, V

ST

< 1 µA.

Timing Diagram

Figure 3. Line Timing Diagram

Minimum exposure time: Ti min = readout time.

For data rate of 5 MHz: Ti min =

= 608.6 µs.

Note:

It is better to clean the shift registers (with running clocks) and not to stop clocking them
after readout time.

Table 1. DC Characteristics

Parameter

Symbol

Value

Unit

Min.

Typ.

Max.

Output Amplifier Drain Supply

V

DD1-2

, V

DD3-4

14.5

15

15.5

V

Substrate Voltage

V

SS

0

0

V

Reset DC Bias

V

DR1

, V

DR2

, V

DR3

, V

DR4

V

DD

- 0.5

V

Output Amplifier Source Bias

V

S1

, V

S2

, V

S3

, V

S4

0

V

Output Gate DC Bias

V

GS1-2

, V

GS3-4

2.2

2.4

2.6

V

Photosensitive Zone DC Bias

V

ST

3.5

4

4.5

V

Antiblooming Diode Bias

VA

1-2

, VA

3-4

14

14.5

15

V

Φ

P3-4

Φ

P1-2

Φ

Φ

LS1-2,

LS3-4

Φ

Φ

R1-2,

R3-4

Φ

Ec1

(clamp)

External

Φ

Ech

(Sampling)

Detailed timing diagram

for transfert from

photosite to register

(see fig. 4)

Detailed pixel

timing diagram

(see fig. 5)

Φ

Φ

L1,

L2

Readout time for line M

Cleaning

Pixel N

Integration time Ti for line M+1

3043

5 MHz

-----------------

Advertising