Figure 6. fault management flowchart – Rainbow Electronics MAX5960 User Manual

Page 20

Advertising
background image

MAX5959/MAX5960

Quad PCI Express, Hot-Plug Controllers

20

______________________________________________________________________________________

ENABLE CHARGE ON

INTERNAL AUXILIARY

MOSFET DRIVING 3.3AUXO_.

START COUNTING t

SU

FAULT ON 12V

OR 3.3V OUTPUTS

RESET t

FAULT

COUNTER

FAULT

STILL PRESENT?

Y

Y

Y

Y

Y

SHUT DOWN

12V AND 3.3V OUTPUTS.

ASSERT FAULT_

STAY WAITING FOR

t

RESTART

t

FAULT

ELAPSED?

N

N

N

N

3.3VAUXIN IS OK,

AUXON_ IS HIGH,

PRES_DET IS LOW

RESET FAULT_

START COUNTING

t

FAULT

Y

N

N

N

ARE ALL

MAIN OUTPUTS OK?

NO FAULT
DETECTED

LATCH-OFF

OPTION?

N

ON_ TOGGLED

HIGH

≥ LOW ≥ HIGH

MAIN INPUTS ARE

OK, ON_ IS HIGH

Y

Y

N

ENABLE CHARGE

ON 3.3G_ AND 12G_.

START

COUNTING t

SU

t

SU

ELAPSED?

Y

START PGOOD

THRESHOLD

MONITORING

START COUNTING

t

FAULT

ALL PGOOD

THRESHOLDS

REACHED?

N

N

N

N

Y

Y

Y

Y

ASSERT PWRGD_

AFTER t

POR_HL

DELAY

RESET PWRGD_

POWER ON

AUXILIARY OUTPUT.

FAULT_ AND PWRGD_ ARE

HIGH IMPEDANCE

SHUT DOWN ALL OUTPUTS.

ASSERT FAULT_.

STAY WAITING

FOR t

RESTART

RESET FAULT_

ON_ AND

AUXON_ TOGGLED

HIGH

≥ LOW

≥ HIGH

t

SU

ELAPSED?

AUX OUTPUT OK?

NO FAULT DETECTED

FAULT ON 3.3AUXO_?

N

N

t

FAULT

ELAPSED?

Y

FAULT

STILL PRESENT?

N

Y

Y

LATCH-OFF

OPTION?

RESET t

FAULT

COUNTER

Figure 6. Fault Management Flowchart