AC ELECTRICAL CHARACTERISTICS

(V

CC

= +2.0V to +5.5V, T

A

= -40

°C to +85°C. Typical values are at V

CC

= +3.3V, T

A

= +25

°C, unless otherwise noted.) (Figure 5,

Notes 1, 4)

PARAMETER

SYMBOL

CONDITIONS

MIN

TYP

MAX

UNITS

OSCILLATOR

X1 to Ground
Capacitance

25

pF

X2 to Ground
Capacitance

25

pF

SPI SERIAL TIMING

Maximum Input Rise
Time

t

rIN

DIN, SCLK,

CS

2

µs

Maximum Input Fall
Time

t

fIN

DIN, SCLK,

CS

2

µs

Output Rise Time

t

rOUT

DOUT, C

LOAD

= 100pF

10

ns

Output Fall Time

t

fOUT

DOUT, C

LOAD

= 100pF

10

ns

V

CC

= +2V

1000

SCLK Period

t

CP

V

CC

= +5V

238

ns

SCLK High Time

t

CH

100

ns

SCLK Low Time

t

CL

100

ns

SCLK Fall to DOUT
Valid

t

DO

C

LOAD

= 100pF

100

ns

DIN to SCLK Setup
Time

t

DS

100

ns

DIN to SCLK Hold
Time

t

DH

2

ns

SCLK Rise to

CS

Rise Hold Time

t

CSH

2

ns

CS High Pulse Width

t

CSW

200

ns

CS High to DOUT
High Impedance

t

CSZ

100

ns

CS to SCLK Setup
Time

t

CSS

100

ns

Note 1: All parameters are 100% tested at T

A

= +25°C. Limits over temperature are guaranteed by design and characterization and

not production tested.

Note 2: I

CC

is specified with DOUT open, CS = DIN = GND, SCLK = 4MHz at V

CC

= +5V; SCLK = 1MHz at V

CC

= +2.0V.

Note 3: Timekeeping current is specified with CS = V

CC

, SCLK = DIN = GND, DOUT = 100k

Ω to GND.

Note 4: All values referred to V

IH

min and V

IL

max levels.