Rainbow Electronics MAX16071 User Manual

Page 23

Advertising
background image

12-Channel/8-Channel, Flash-Configurable System

Managers with Nonvolatile Fault Registers

MAX16070/MAX16071

______________________________________________________________________________________ 23

The general-purpose inputs/outputs (GPIO1 to GPIO8)
can be configured as ANY_FAULT outputs or dedicated
Fault1 and Fault2 outputs to indicate fault conditions.
These fault outputs are not masked by the critical fault
enable bits shown in Table 14. See the General-Purpose
Inputs/Outputs
section for more information on configur-
ing GPIO_s as fault outputs.

Deglitch

Fault conditions are detected at the end of each conver-
sion. When the voltage on an input falls outside a moni-
tored threshold for one acquisition, the input multiplexer
remains on that channel and performs several succes-
sive conversions. To trigger a fault, the input must stay

outside the threshold for a certain number of acquisitions
as determined by the deglitch setting in r73h[6:5] and
r74h[6:5] (see Table 12).

Fault Flags

Fault flags indicate the fault status of a particular input.
The fault flag of any monitored input in the device can be
read at any time from registers r1Bh and r1Ch, as shown
in Table 13. Clear a fault flag by writing a ‘1’ to the appro-
priate bit in the flag register. Unlike the fault signals sent
to the fault outputs, these bits are masked by the Critical
Fault Enable bits (see Table 14). The fault flag is only set
when the matching enable bit in the critical fault enable
register is also set.

Table

12. Deglitch Configuration

Table

13. Fault Flags

REGISTER

ADDRESS

FLASH

ADDRESS

BIT RANGE

DESCRIPTION

73h

273h

[6:5]

Overcurrent comparator deglitch time
00 = No deglitch
01 = 4ms
10 = 15ms
11 = 60ms

74h

274h

[6:5]

Voltage comparator deglitch configuration
00 = 2 cycles
01 = 4 cycles
10 = 8 cycles
11 = 16 cycles

REGISTER

ADDRESS

BIT RANGE

DESCRIPTION

1Bh

[0]

MON1

[1]

MON2

[2]

MON3

[3]

MON4

[4]

MON5

[5]

MON6

[6]

MON7

[7]

MON8

1Ch

[0]

MON9

[1]

MON10

[2]

MON11

[3]

MON12

[4]

Overcurrent

[5]

External fault (EXTFAULT)

[6]

SMB alert