Table 26. maximum write time – Rainbow Electronics MAX16071 User Manual

Page 42

Advertising
background image

12-Channel/8-Channel, Flash-Configurable System

Managers with Nonvolatile Fault Registers

MAX16070/MAX16071

42 _____________________________________________________________________________________

The capacitor value depends on V

IN

and the time delay

required, t

FAULT_SAVE

. Use the following formula to cal-

culate the capacitor size:

C = (t

FAULT_SAVE

x I

CC(MAX)

)/(V

IN

- V

DIODE

- V

UVLO

)

where the capacitance is in Farads and t

FAULT_SAVE

is in

seconds, I

CC(MAX)

is 14mA, V

DIODE

is the voltage drop

across the diode, and V

UVLO

is 2.7V. For example, with

a V

IN

of 14V, a diode drop of 0.7V, and a t

FAULT_SAVE

of 153ms, the minimum required capacitance is 202FF.

Table 26. Maximum Write Time

Figure

14. Power Circuit for Shutdown During Fault Conditions

Figure

15. Graphical User Interface Screenshot

R6Dh[1:0]

VALUE

DESCRIPTION

MAXIMUM

WRITE TIME

(ms)

00

Save flags and ADC
readings

153

01

Save flags

102

10

Save ADC readings

153

11

Do not save anything

MAX16070