MAX9597

Low-Power Audio/Video Interface

for Single SCART Connectors

______________________________________________________________________________________

25

The MAX9597 provides separate ground connections
for video and audio supplies. For best performance,
use separate ground planes for each of the ground
returns and connect all ground planes together at a sin-
gle point. Refer to the MAX9597 Evaluation Kit for a
proven circuit board layout example.

If the MAX9597 is mounted using flow soldering or
wave soldering, the ground via(s) for the exposed pad
should have a finished hole size of at least 14mil to
ensure adequate wicking of soldering onto the exposed
pad. If the MAX9597 is mounted using the solder mask
technique, the via requirement does not apply. In either
case, a good connection between the exposed pad
and ground is required to minimize noise from coupling
onto the outputs.

4

3

2

1

I

2

C INTERFACE

AND REGISTERS

MAX9597

VIDEO FILTERS

AUDIO

WITH DirectDrive

OUTPUTS

SLOW SWITCHING

FAST SWITCHING

CHARGE PUMP

V

12

V

AUD

V

ID

3.3V

3.3V

EP

GND

μC

VIDEO

ENCODER

STEREO

AUDIO

DAC

CVBS, Y/C

SINGLE OR

DIFFERENTIAL

STEREO AUDIO

STB CHIP

CVBS

Y

C

LEFT AUDIO

RIGHT AUDIO

I

2

C

N.C.

Figure 18. Set-Top Box with CVBS Output, S-Video Output, and Stereo Audio Outputs