MAX5943

FireWire Current Limiter and Low-Drop
ORing Switch Controller

14

______________________________________________________________________________________

Undervoltage Lockout

The MAX5943 operates from 7.5V to 37V and has a
default 6.5V undervoltage lockout threshold. The external
MOSFETs remain off as long as V

IN

> 6.5V and V

ON

<

V

ON_REF

. The turn-on threshold is programmable by

connecting a resistor-divider at ON. When V

ON

> 1.24V

and V

IN

> 7.5V, GATE2 is enhanced to 5.5V, with respect

to OUT and the MAX5943 goes into normal operation.

Program the MAX5943’s turn-on voltage using the fol-
lowing formula:

where V

TURN_ON

is the desired turn-on voltage of the

MAX5943. Choose an R2 value in the 1kΩ range to
minimize error due to the ON bias current.

When operating the MAX5943, ON must remain above
its 1.24V threshold. If V

ON

falls below its 1.24V thresh-

old, the power-supply MOSFETs (Q1 and Q2) turn off
immediately (less than 1µs). This allows the power sup-
ply to disconnect in the event of a fault condition

detected by the system, such as shorting of the output
to a different power-supply voltage or a FireWire signal
pin. If possible transient conditions exist at the main
power-supply line (IN), place an RC filter at ON to
reject transient voltage dips and to prevent unneces-
sary power-supply interruptions.

R

V

R

TURN ON

1

1 24

1

2

=

 ×

_

.

V

INA

I

INA

I

INB

V

INB

V

INB

> V

INA

V

OUT

Figure 6. MAX5943 Power Switch Over ORing Timing Diagram

SENSE GATE1

OR_ADJ

GND

LATCH

ILIM

GATE2

PORT1

OUT

IN

MAX5943

TIM

ON

ONQ1

FAULT

SENSE GATE1

OR_ADJ

GND

LATCH

ILIM

GATE2

PORT2

OUT

IN

MAX5943

TIM

ON

ONQ1

FAULT

Figure 7. MAX5943 Operating in Reverse-Current Mode
(Routing Power from Port 1 to Port 2)

MAX5943

R2

R1

V

IN

IN

GND

ON

Figure 8. Setting the MAX5943 Turn-On Voltage