MAX5943

FireWire Current Limiter and Low-Drop

ORing Switch Controller

_______________________________________________________________________________________

9

Pin Description

PIN

NAME

FUNCTION

1

ON

On/Off-Control Input. ON sets the undervoltage lockout threshold and resets the part after a fault latch.
Drive ON high to enable the device. Drive ON low to disable the device. Connect ON to IN for the default
undervoltage lockout threshold. Connect a resistor-divider from IN to ON and GND to program the desired
undervoltage lockout threshold.

2

FAULT

Current-Fault, Active-Low, Open-Drain Output.

FAULT asserts and latches low after a current-limit/circuit-

breaker fault has exceeded the current-limit/circuit-breaker timeout period (see the

FAULT

section).

3

TIM

Current-Limit/Circuit-Breaker Timeout Adjustment Input. Connect TIM to IN for the default timeout period or
connect a resistor from TIM to GND to program the current-limit/circuit-breaker timeout period.

4

ILIM

Current-Limit/Circuit-Breaker Threshold Input. Leave ILIM open for a 40mV circuit-breaker threshold,
connect to GND for a 50mV circuit-breaker threshold, or connect to IN for a 60mV circuit-breaker threshold
(see the Current Limiting section).

5

LATCH

Latch or Autoretry Fault Management Selection Input. Connect LATCH to IN to select latch-off mode
after a current-limit/circuit-breaker timeout. Connect LATCH to GND for autorestart mode after a current-
limit/circuit-breaker timeout.

6

OR_ADJ

ORing Switch Turn-On Current Threshold Adjustment Input. Select one of three ORing switch turn-on
threshold settings: connect OR_ADJ to GND, connect OR_ADJ to IN, or leave OR_ADJ floating (see the
Power-Supply ORing section).

7, 10, 13

N.C.

No Connection. Not internally connected.

8

ONQ1

ORing Switch Manual Turn-On Input. Drive ONQ1 low to enable power-supply ORing. Drive ONQ1 high
to set GATE1 high to allow reverse current flow. ONQ1 is disabled when V

IN

is below the UVLO threshold,

V

ON

is below the V

ON_REF

threshold, and after a current/circuit-breaker fault.

9

GND

Ground

11

OUT

Output Voltage Sense. Connect to the output.

12

GATE2

Current-Limiter Switch Gate Drive Output. Connect GATE2 to the gate of the 2nd n-channel MOSFET.
GATE2 is a charge pump with a 45µA pullup current to 5.5V (typ) above OUT when active (see the Typical
Operating Circuit
).

14

GATE1

ORing Switch Gate-Drive Output. Connect GATE1 to the gate of the 1st n-channel MOSFET. GATE1 is a
charge pump with a 45µA pullup current to 5.5V (typ) above SENSE when active (see the Typical
Operating Circuit
).

15

SENSE

Current-Sense Negative Input. Connect a current-sense resistor, R

SENSE,

from IN to SENSE (see the

Typical Operating Circuit).

16

IN

Input Power and Current-Sense Positive Input. Connect IN to the positive terminal of the current-sense
resistor and to the power source (see the Typical Operating Circuit).