Program cycle characteristics, Software protected program waveform, Programming algorithm(1) – Rainbow Electronics AT29LV040A User Manual

Page 9: Programming algorithm

Advertising
background image

9

AT29LV040A

0334F–FLASH–05/02

Software Protected Program Waveform

Notes:

1. OE must be high when WE and CE are both low.
2. A8 through A18 must specify the sector address during each high-to-low transition of WE (or CE) after the software code

has been entered.

3. All words that are not loaded within the sector being programmed will be indeterminate.

Programming Algorithm

(1)

Program Cycle Characteristics

Symbol

Parameter

Min

Max

Units

t

WC

Write Cycle Time

20

ms

t

AS

Address Set-up Time

10

ns

t

AH

Address Hold Time

100

ns

t

DS

Data Set-up Time

100

ns

t

DH

Data Hold Time

10

ns

t

WP

Write Pulse Width

200

ns

t

BLC

Byte Load Cycle Time

150

µs

t

WPH

Write Pulse Width High

200

ns

LOAD DATA AA

TO

ADDRESS 5555

LOAD DATA 55

TO

ADDRESS 2AAA

LOAD DATA A0

TO

ADDRESS 5555

LOAD DATA

TO

SECTOR (256 BYTES)

(3)

WRITES ENABLED

ENTER DATA

PROTECT STATE

(2)

Notes:

1. Data Format: I/O7 - I/O0 (Hex);

Address Format: A14 - A0 (Hex).

2. Data Protect state will be re-activated at

end of program cycle.

3. 256 bytes of data MUST BE loaded.

Advertising