Power down / power up timing, Ta=25°c), Warning – Rainbow Electronics DS12C887 User Manual

Page 18

Advertising
background image

DS12C887

18 of 19

POWER DOWN / POWER UP TIMING

PARAMETER

SYMBOL

MIN

TYP

MAX

UNITS

NOTES

CS

at V

IH

before Power-

Down

t

PD

0

µ

s

V

CC

slew from 4.5V to 0V

(

CS

at V

IH

)

t

F

4.0

V

CC

4.5V

300

µ

s

V

CC

slew from 0V to 4.5V

(

CS

at V

IH

)

t

R

100

µ

s

CS

at V

IH

after Power-Up

t

REC

20

200

ms

Expected Data Retention

t

DR

10

years

10,11

(tA=25°C)

PARAMETER

SYMBOL

MIN

TYP

MAX

UNITS

NOTES

Expected Data Retention

t

DR

10

years

10,11

Note:

The real time clock will keep time to an accuracy of

±

1 minute per month during data retention time for

the period of t

DR

.

Warning:

Under no circumstances are negative undershoots, of any amplitude, allowed when device is in battery
back-up mode.