DS12C887

3 of 19

R/ W (Read/Write Input) – The R/ W pin also has two modes of operation. When the MOT pin is
connected to V

CC

for Motorola timing, R/W is at a level which indicates whether the current cycle is a

read or write. A read cycle is indicated with a high level on R/W while DS is high. A write cycle is
indicated when R/ W is low during DS. When the MOT pin is connected to GND for Intel timing, the
R/ W signal is an active low signal called WR. In this mode the R/ W pin has the same meaning as the
Write Enable signal (WE) on generic RAMs.

CS

(Chip Select Input) – The Chip Select signal must be asserted low for a bus cycle in the DS12C887

to be accessed.

CS

must be kept in the active state during DS and AS for Motorola timing and during RD

and WR for Intel timing. Bus cycles which take place without asserting

CS

will latch addresses but no

access will occur. When V

CC

is below 4.25 volts, the DS12C887 internally inhibits access cycles by

internally disabling the

CS

input. This action protects both the real time clock data and RAM data during

power outages.

IRQ

(Interrupt Request Output) - The

IRQ

pin is an active low output of the DS12C887 that can be

used as an interrupt input to a processor. The

IRQ

output remains low as long as the status bit causing the

interrupt is present and the corresponding interrupt-enable bit is set. To clear the

IRQ

pin the processor

program normally reads the C register. The RESET pin also clears pending interrupts. When no interrupt
conditions are present, the

IRQ

level is in the high impedance state. Multiple interrupting devices can be

connected to an

IRQ

bus. The IRQ bus is an open drain output and requires an external pull-up resistor.

RESET

(Reset Input) – The RESET pin has no effect on the clock, calendar, or RAM. On power-up the

RESET pin can be held low for a time in order to allow the power supply to stabilize. The amount of

time that RESET is held low is dependent on the application. However, if RESET is used on power–up,
the time RESET is low should exceed 200 ms to make sure that the internal timer that controls the
DS12C887 on power-up has timed out. When RESET is low and V

CC

is above 4.25 volts, the following

occurs:

A. Periodic Interrupt Enable (PEI) bit is cleared to zero.
B. Alarm Interrupt Enable (AIE) bit is cleared to zero.
C. Update Ended Interrupt Flag (UF) bit is cleared to zero.
D. Interrupt Request Status Flag (IRQF) bit is cleared to zero.
E. Periodic Interrupt Flag (PF) bit is cleared to zero.
F. The device is not accessible until RESET is returned high.
G. Alarm Interrupt Flag (AF) bit is cleared to zero.
H.

IRQ

pin is in the high impedance state.

I. Square Wave Output Enable (SQWE) bit is cleared to zero.
J. Update Ended Interrupt Enable (UIE) is cleared to zero.

In a typical application RESET can be connected to V

CC

. This connection will allow the DS12C887 to

go in and out of power fail without affecting any of the control registers.