Software product identification entry(1), Software product identification exit(1), Software product identification entr y – Rainbow Electronics AT29LV512 User Manual

Page 10: Software product identification exit

Advertising
background image

10

AT29LV512

0177M–05/02

Software Product Identification Entry

(1)

Notes:

1. Data Format: I/O7 - I/O0 (Hex); Address Format: A14 - A0 (Hex).
2. A1 - A15 = V

IL

. Manufacturer Code is read for A0 = V

IL

; Device Code is read for A0 = V

IH

.

3. The device does not remain in identification mode if powered down.
4. The device returns to standard operation mode.
5. Manufacturer Code is 1F. The Device Code is 3D.

Software Product Identification Exit

(1)

LOAD DATA AA

TO

ADDRESS 5555

LOAD DATA 55

TO

ADDRESS 2AAA

LOAD DATA 90

TO

ADDRESS 5555

PAUSE 20 mS

ENTER PRODUCT

IDENTIFICATION

MODE

(2)(3)(5)

LOAD DATA AA

TO

ADDRESS 5555

LOAD DATA 55

TO

ADDRESS 2AAA

LOAD DATA F0

TO

ADDRESS 5555

PAUSE 20 mS

EXIT PRODUCT

IDENTIFICATION

MODE

(4)

Advertising