Flash programming and verification characteristics, Flash programming and verification waveforms – Rainbow Electronics АТ89С2051 User Manual
Page 8
Advertising
AT89C2051
8
Note:
1. Only used in 12-volt programming mode.
Flash Programming and Verification Waveforms
Flash Programming and Verification Characteristics
T
A
= 0°C to 70°C, V
CC
= 5.0
± 10%
Symbol
Parameter
Min
Max
Units
V
PP
Programming Enable Voltage
11.5
12.5
V
I
PP
Programming Enable Current
250
µA
t
DVGL
Data Setup to PROG Low
1.0
µs
t
GHDX
Data Hold after PROG
1.0
µs
t
EHSH
P3.4 (ENABLE) High to V
PP
1.0
µs
t
SHGL
V
PP
Setup to PROG Low
10
µs
t
GHSL
V
PP
Hold after PROG
10
µs
t
GLGH
PROG Width
1
110
µs
t
ELQV
ENABLE Low to Data Valid
1.0
µs
t
EHQZ
Data Float after ENABLE
0
1.0
µs
t
GHBL
PROG High to BUSY Low
50
ns
t
WC
Byte Write Cycle Time
2.0
ms
t
BHIH
RDY/BSY\ to Increment Clock Delay
1.0
µs
t
IHIL
Increment Clock High
200
ns