Rainbow Electronics AT90LS2343 User Manual

Page 41

Advertising
background image

41

AT90S/LS2323/2343

1004D–09/01

Note:

a = address high bits
b = address low bits
i = data in
o = data out
x = don’t care
1 = Lock Bit1
2 = Lock Bit2
F = FSTRT Fuse
R = RCEN Fuse
S = SPIEN Fuse

Read Fuse
and Lock Bits
(AT90S/
LS2323)

PB0

PB1

PB2

0_0000_0100_00

0_0100_1100_00

x_xxxx_xxxx_xx

0_0000_0000_00

0_0111_1000_00

x_xxxx_xxxx_xx

0_0000_0000_00

0_0111_1100_00

1_2Sxx_xxRx_xx

Reading 1, 2, S, R = “0” means
the Fuse/Lock bit is
programmed.

Read Fuse
and Lock Bits
(AT90S/
LS2343)

PB0

PB1

PB2

0_0000_0100_00

0_0100_1100_00

x_xxxx_xxxx_xx

0_0000_0000_00

0_0111_1000_00

x_xxxx_xxxx_xx

0_0000_0000_00

0_0111_1100_00

1_2Sxx_xxRx_xx

Reading 1, 2, S, R = “0” means
the Fuse/Lock bit is
programmed.

Read
Signature
Bytes

PB0

PB1

PB2

0_0000_1000_00

0_0100_1100_00

x_xxxx_xxxx_xx

0_0000_00bb_00

0_0000_1100_00

x_xxxx_xxxx_xx

0_0000_0000_00

0_0110_1000_00

x_xxxx_xxxx_xx

0_0000_0000_00

0_0110_1100_00

o_oooo_ooox_xx

Repeat Instr.2 - Instr.4 for each
signature byte address.

Table 16. High-voltage Serial Programming Instruction Set (Continued)

Instruction

Instruction Format

Operation Remarks

Instr.1

Instr.2

Instr.3

Instr.4

Advertising