Dc and ac operating conditions for read operation – Rainbow Electronics AT27LV520 User Manual

Page 4

Advertising
background image

AT27LV520

4

Note:

1. V

CC

standby current will be slightly higher with ALE, Ai, and ADi at TTL levels.

DC and AC Operating Conditions for Read Operation

AT27LV520-70

AT27LV520-90

Operating Temp. (Case)

Com.

0°C - 70°C

0°C - 70°C

Ind.

-40°C - +85°C

-40°C - +85°C

V

CC

Supply

3.0V to 3.6V

3.0V to 3.6V

5V

±=10%

5V

±=10%

DC and Operating Characteristics for Read Operation

Symbol

Parameter

Condition

Min

Max

Units

V

CC

= 3.0V to 3.6V

I

LI

Input Load Current

V

IN

= 0V to V

CC

±1

µA

I

LO

Output Leakage Current

V

OUT

= 0V to V

CC

±5

µA

I

SB

(1)

V

CC

Standby Current

ALE = V

CC

± 0.3V; Ai, ADi = GND/V

CC

± 0.3V

20

µA

I

CC

V

CC

Active Current

f = 5 MHz, I

OUT

= 0 mA, ALE = V

IL

8

mA

V

IL

Input Low Voltage

-0.6

0.8

V

V

IH

Input High Voltage

2.0

V

CC

+ 0.5

V

V

OL

Output Low Voltage

I

OL

= 2.0 mA

0.4

V

V

OH

Output High Voltage

I

OH

= -2.0 mA

2.4

V

V

CC

= 4.5V to 5.5V

I

LI

Input Load Current

V

IN

= 0V to V

CC

±1

µA

I

LO

Output Leakage Current

V

OUT

= 0V to V

CC

±5

µA

I

SB

(1)

V

CC

Standby Current

ALE = V

CC

± 0.3V; Ai, ADi = GND/V

CC

± 0.3V

100

µA

I

CC

V

CC

Active Current

f = 5 MHz, I

OUT

= 0 mA, ALE = V

IL

20

mA

V

IL

Input Low Voltage

-0.6

0.8

V

V

IH

Input High Voltage

2.0

V

CC

+ 0.5

V

V

OL

Output Low Voltage

I

OL

= 2.1 mA

0.4

V

V

OH

Output High Voltage

I

OH

= -400 µA

2.4

Advertising