Rapid™ programming algorithm, Rapid, Programming algorithm – Rainbow Electronics AT27LV520 User Manual

Page 9

Advertising
background image

AT27LV520

9

Rapid

Programming Algorithm

A 50 µs ALE pulse width is used to program. The address
is set to the first location. V

CC

is raised to 6.5V and OE/V

PP

is raised to 13.0V. Each address is first programmed with
one 50 µs ALE pulse without verification. Then a verifica-
tion/reprogramming loop is executed for each address. In
the event a byte fails to pass verification, up to 10 succes-
sive 50 µs pulses are applied with a verification after each

pulse. If the byte fails to verify after 10 pulses have been
applied, the part is considered failed. After the byte verifies
properly, the next address is selected until all have been
checked. OE/V

PP

is then lowered to V

IH

and V

CC

to 5.0V. All

bytes are read again and compared with the original data to
determine if the device passes or fails.

START

ADDR = FIRST LOCATION

ADDR = FIRST LOCATION

VCC = 6.5V

VPP = 13.0V

VCC = 5.0V

VPP = 5.0V

PROGRAM ONE 50 µS PULSE

PROGRAM ONE 50 µS PULSE

LAST

ADDR.?

LAST

ADDR.?

NO

NO

NO

X = 0

X = 10?

INCREMENT X

VERIFY

BYTE

DEVICE

FAILED

DEVICE

PASSED

COMPARE

ALL BYTES

TO ORIGINAL

DATA

YES

YES

YES

INCREMENT ADDRESS

INCREMENT ADDRESS

PASS

PASS

FAIL

FAIL

Advertising