AT88SA100S [ Preliminary]

15

8558A–SMEM–03/09

4.3.

BurnFuse

Burns one of the 88 user accessible fuse bits.

The power supply pin must meet the V

BLOW

specification in order to burn fuses reliably. If the voltage is too low then the

actual fuse blow will not be attempted and the chip will return the error code. If the watchdog timer is within t

EXEC_FUSE

of

its expiration, this command will also be aborted and return an error.

The values in fuses #88-127 are reserved for the MfrID and SerialNumber and cannot be blown via this command. All
addresses above 0x4C (87) will result in an error.

Fuses, with the exception of those initialized by Atmel, have a value of 1 on shipment from the Atmel factory and
transition to a 0 when they are burned.

Fuse bits #0 through #7 of the fuse array are word lock bits. Burning one of these has the effect of locking the
corresponding 16 bit word within Fuse. Bit 0 locks fuses 0-15, bit 1 locks fuses 16-31 and so on. If bit 0 is burned, then
the value of the lock bits can no longer be changed. The values of lock bits 6 & 7 are ignored by the chip.

There is a very small interval during t

EXEC_FUSE

when the fuse element is actually being blown. The power supply must

not be removed during this interval, or the fuse may end up in a state where it reads as un-blown but cannot be burned.

Table 13.

Input Parameters

Name

Size

Notes

Opcode BURNFUSE

1

0x04

Param1

Address

1

Must be 0x00 00

Param2

Zero

2

Should be all 0’s

Data –

0

Table 14.

Output Parameters

Name

Size

Notes

Success

1

Upon successful completion, a value of 0 will be returned by the device.