Dc and ac operating conditions, Dc characteristics, Atf1502as(l) – Rainbow Electronics ATF1502ASL User Manual

Page 13

Advertising
background image

13

ATF1502AS(L)

0995J–PLD–09/02

Notes:

1. Not more than one output at a time should be shorted. Duration of short circuit test should not exceed 30 sec.
2. I

CC3

refers to the current in the reduced-power mode when macrocell reduced-power is turned on.

DC and AC Operating Conditions

Commercial

Industrial

Operating Temperature (Ambient)

0

°C - 70°C

-40

°C - 85°C

V

CC

(5V) Power Supply

5V

± 5%

5V

± 10%

DC Characteristics

Symbol

Parameter

Condition

Min

Typ

Max

Units

I

IL

Input or I/O Low
Leakage Current

V

IN

= V

CC

-2

-10

µA

I

IH

Input or I/O High
Leakage Current

2

10

I

OZ

Tri-state Output
Off-state Current

V

O

= V

CC

or GND

-40

40

µA

I

CC1

Power Supply Current, Standby

V

CC

= Max

V

IN

= 0, V

CC

Std Mode

Com.

60

mA

Ind.

75

mA

“L” Mode

Com.

10

µA

Ind.

10

µA

I

CC2

Power Supply Current,
Power-down Mode

V

CC

= Max

V

IN

= 0, V

CC

“PD” Mode

1

5

mA

I

CC3

(2)

Reduced-power Mode
Supply Current, Standby

V

CC

= Max

V

IN

= 0, V

CC

Std Mode

Com.

35

mA

Ind.

40

mA

V

IL

Input Low Voltage

-0.3

0.8

V

V

IH

Input High Voltage

2.0

V

CCIO

+ 0.3

V

V

OL

Output Low Voltage (TTL)

V

IN

= V

IH

or V

IL

V

CC

= MIN, I

OL

= 12 mA

Com.

3.0

0.45

V

Ind.

0.45

Output Low Voltage (CMOS)

V

IN

= V

IH

or V

IL

V

CC

= MIN, I

OL

= 0.1 mA

Com.

0.2

V

Ind.

0.2

V

V

OH

Output High Voltage (TTL)

V

IN

= V

IH

or V

IL

V

CC

= MIN, I

OH

= -4.0 mA

2.4

V

Advertising