Ac electrical characteristics (-40°c to +85°c, v, 7v to 5.5v) – Rainbow Electronics DS1855 User Manual

Page 14

Advertising
background image

DS1855

14 of 20

AC ELECTRICAL CHARACTERISTICS

(-40°C to +85°C, V

CC

= 2.7V to 5.5V)

PARAMETER

SYMBOL CONDITION

MIN

TYP

MAX

UNITS NOTES

SCL Clock Frequency

f

SCL

Fast Mode

Standard Mode

0
0

400
100

kHz

4

Bus Free Time Between
STOP and START

t

BUF

Fast Mode

Standard Mode

1.3
4.7

ms

4

Hold Time (repeated)
START Condition

t

HD:STA

Fast Mode

Standard Mode

0.6
4.0

ms

4,5

Low Period of SCL
Clock

t

LOW

Fast Mode

Standard Mode

1.3
4.7

ms

4

High Period of SCL
Clock

t

HIGH

Fast Mode

Standard Mode

0.6
4.0

ms

4

Data Hold Time

t

HD:DAT

Fast Mode

Standard Mode

0
0

0.9
0.9

ms

4,6

Data Set-Up Time

t

SU:DAT

Fast Mode

Standard Mode

100
250

ns

4

Start Set-Up Time

t

SU:STA

Fast Mode

Standard Mode

0.6
4.7

ms

4

Rise Time of Both SDA
and SCL Signals

t

R

Fast Mode

Standard Mode

20+0.1CB

300

1000

ns

4

Fall Time of Both SDA
and SCL Signals

t

F

Fast Mode

Standard Mode

20+0.1CB

300
300

ns

7

Set-Up Time for STOP
Condition

t

SU:STO

Fast Mode

Standard Mode

0.6
4.0

ms

Capacitive Load for
Each Bus Line

C

B

400

pF

7

EEPROM Write Time

T

W

2.5

10

ms

8

NONVOLATILE MEMORY CHARACTERISTICS

PARAMETER

SYMBOL CONDITION

MIN

TYP

MAX

UNITS

Writes

+85

°

C

50,000

Advertising