Digital thermometer, Analog voltage monitoring, Analog resistor characteristics – Rainbow Electronics DS1854 User Manual

Page 3

Advertising
background image

DS1854

Dual Temperature-Controlled Resistors with

Two Monitors

_____________________________________________________________________

3

PARAMETER

SYMBOL

CONDITIONS

TYP

MAX

UNITS

Thermometer Error

T

ERR

-40°C to +95°C

±3.0

°C

DIGITAL THERMOMETER

(V

CC

= 3.0V to 5.5V, T

A

= -40°C to +95°C, unless otherwise noted.)

PARAMETER

SYMBOL

CONDITIONS

MIN

TYP

MAX

UNITS

Input Resolution

∆VMON

610

µV

Supply Resolution

∆V

CC

1.6

mV

Input/Supply Accuracy

A

CC

0.25

0.5

% FS

(full scale)

Update Rate for MON1, MON2,
Temp, or V

CC

t

frame

20

30

ms

ANALOG VOLTAGE MONITORING

(V

CC

= 3.0V to 5.5V, T

A

= -40°C to +95°C, unless otherwise noted.)

PARAMETER

SYMBOL

CONDITIONS

MIN

TYP

MAX

UNITS

Position 00h Resistance

T

A

= +25°C

0.7

1.0

1.25

k

Position FFh Resistance

T

A

= +25°C

40

50

60

k

Absolute Linearity

(Note 6)

-2

+2

LSB

Relative Linearity

(Note 7)

-1

+1

LSB

Temperature Coefficient

(Note 8)

50

ppm/°C

High-Z Resistor Current

I

RHIZ

RHIZ = V

CC

0.1

µA

ANALOG RESISTOR CHARACTERISTICS

(V

CC

= 3.0V to 5.5V, T

A

= -40°C to +95°C, unless otherwise noted.)

Advertising