Dc and ac operating conditions for read operation, Ac characteristics for read operation – Rainbow Electronics AT27C256R User Manual

Page 4

Advertising
background image

AT27C256R

4

Notes:

1. V

CC

must be applied simultaneously with or before V

PP

, and removed simultaneously with or after V

PP

..

2. V

PP

may be connected directly to V

CC

, except during programming. The supply current would then be the sum of I

CC

and I

PP

..

Note:

2, 3, 4, 5. - see AC Waveforms for Read Operation.

DC and AC Operating Conditions for Read Operation

AT27C256R

-45

-55

-70

-90

-12

-15

Operating
Temp. (Case)

Com.

0

°

C - 70

°

C

0

°

C - 70

°

C

0

°

C - 70

°

C

0

°

C - 70

°

C

0

°

C - 70

°

C

0

°

C - 70

°

C

Ind.

-40

°

C - 85

°

C

-40

°

C - 85

°

C

-40

°

C - 85

°

C

-40

°

C - 85

°

C

-40

°

C - 85

°

C

-40

°

C - 85

°

C

Auto.

-40

°

C - 125

°

C

-40

°

C - 125

°

C

-40

°

C - 125

°

C

-40

°

C - 125

°

C

V

CC

Supply

5V

±

10%

5V

±

10%

5V

±

10%

5V

±

10%

5V

±

10%

5V

±

10%

DC and Operating Characteristics for Read Operation

Symbol

Parameter

Condition

Min

Max

Units

I

LI

Input Load Current

V

IN

= 0V to V

CC

Com., Ind.

±

1

µ

A

Auto.

±

5

µ

A

I

LO

Output Leakage Current

V

OUT

= 0V to V

CC

Com., Ind.

±

5

µ

A

Auto.

±

10

µ

A

I

PP1

(2)

V

PP

(1)

Read/Standby Current

V

PP

= V

CC

10

µ

A

I

SB

V

CC

(1)

Standby Current

I

SB1

(CMOS), CE = V

CC

±

0.3V

100

µ

A

I

SB2

(TTL), CE = 2.0 to V

CC

+ 0.5V

1

mA

I

CC

V

CC

Active Current

f = 5 MHz, I

OUT

= 0 mA, E = V

IL

20

mA

V

IL

Input Low Voltage

-0.6

0.8

V

V

IH

Input High Voltage

2.0

V

CC

+ 0.5

V

V

OL

Output Low Voltage

I

OL

= 2.1 mA

0.4

V

V

OH

Output High Voltage

I

OH

= -400

µ

A

2.4

V

AC Characteristics for Read Operation

AT27C256R

Units

-45

-55

-70

-90

-12

-15

Symbol

Parameter

Condition

Min

Max

Min

Max

Min

Max

Min

Max

Min

Max

Min

Max

t

ACC

(3)

Address to Output Delay CE = OE = V

IL

45

55

70

90

120

150

ns

t

CE

(2)

CE to Output Delay

OE = V

IL

45

55

70

90

120

150

ns

t

OE

(2)(3)

OE to Output Delay

CE = V

IL

20

25

30

30

35

40

ns

t

DF

(4)(5)

OE or CE High to Output
Float, whichever occurred first

20

20

25

25

30

35

ns

t

OH

Output Hold from Address, CE or OE,
whichever occurred first

7

7

7

0

0

0

ns

Advertising