2 worst case calculation with rwd_osc = 51 kw, 2 worst case calculation with r, 51 k ω – Rainbow Electronics ATA6624 User Manual

Page 16

Advertising
background image

16

4986F–AUTO–07/08

ATA6622/ATA6624/ATA6626

Figure 6-1.

Timing Sequence with R

WD_OSC

= 51 k

Ω

6.2

Worst Case Calculation with R

WD_OSC

= 51 k

Ω

The internal oscillator has a tolerance of 20%. This means that t

1

and t

2

can also vary by 20%.

The worst case calculation for the watchdog period t

wd

is calculated as follows.

The ideal watchdog time t

wd

is between the maximum t

1

and the minimum t

1

plus the minimum

t

2

.

t

1,min

= 0.8

×

t

1

= 16.5 ms, t

1,max

= 1.2

×

t

1

= 24.8 ms

t

2,min

= 0.8

×

t

2

= 17.3 ms, t

2,max

= 1.2

×

t

2

= 26 ms

t

wdmax

= t

1min

+ t

2min

= 16.5 ms + 17.3 ms = 33.8 ms

t

wdmin

= t

1max

= 24.8 ms

t

wd

= 29.3 ms ±4.5 ms (±15%)

A microcontroller with an oscillator tolerance of ±15% is sufficient to supply the trigger inputs
correctly.

t

nres

= 4 ms

Undervoltage Reset

Watchdog Reset

t

reset

= 4 ms

t

trig

> 200 ns

t

1

= 20.6 ms

t

2

= 21 ms

t

2

t

1

t

wd

t

d

= 155 ms

VCC

3.3V/5V

NTRIG

NRES

Table 6-1.

Typical Watchdog Timings

R

WD_OSC

k

Ω

Oscillator

Period

t

osc

/µs

Lead
Time

t

d

/ms

Closed

Window

t

1

/ms

Open Window

t

2

/ms

Trigger Period from

Microcontroller

t

wd

/ms

Reset Time

t

nres

/ms

34

13.3

105

14.0

14.7

19.9

4

51

19.61

154.8

20.64

21.67

29.32

4

91

33.54

264.80

35.32

37.06

50.14

4

120

42.84

338.22

45.11

47.34

64.05

4