Ata6832 – Rainbow Electronics ATA6832 User Manual

Page 5

Advertising
background image

5

4951A–AUTO–08/06

ATA6832

Table 3-2.

Output Data Protocol

Bit

Output (Status)

Register

Function

0

TP

Temperature prewarning: high = warning

1

Status LS1

Normal operation: high = output is on, low = output is off
Open-load detection: high = open load, low = no open load
(correct load condition is detected if the corresponding output is
switched off); not affected by SRR

2

Status HS1

Normal operation: high = output is on, low = output is off
Open-load detection: high = open load, low = no open load
(correct load condition is detected if the corresponding output is
switched off); not affected by SRR

3

Status LS2

Description see LS1

4

Status HS2

Description see HS1

5

Status LS3

Description see LS1

6

Status HS3

Description see HS1

7

n. u.

Not used

8

n. u.

Not used

9

n. u.

Not used

10

n. u.

Not used

11

n. u.

Not used

12

n. u.

Not used

13

OVL

Over-load detected: set high, when at least one output is switched off
by a short-circuit condition or an overtemperature event. Bits 1 to 6 can
be used to detect the affected switch

14

INH

Inhibit: this bit is controlled by software (bit SI in input register)
High = standby, low = normal operation

15

PSF

Power-supply fail: undervoltage at pin VS detected