Note: Some revisions of this device may incorporate deviations from published specifications known as errata. Multiple revisions of any device
may be simultaneously available through various sales channels. For information about device errata, click here:

www.maxim-ic.com/errata

.








FEATURES

§ Two 32-bit counters keep track of real-time

and elapsed time

§ Counters keep track of seconds for over 125

years

§ Battery powered counter counts seconds from

the time battery is attached until V

BAT

is less

than 2.5V

§ V

CC

powered counter counts seconds while

V

CC

is above V

T P

and retains the count in the

absence of V

CC

under battery backup power

§ Clear function resets selected counter to 0
§ Read/write serial port affords low pin count
§ Maximum current drain of less than 1 µA

from V

BAT

pin when serial port is disabled

§ One byte protocol defines read/write, counter

address and software clear function

§ 8-pin DIP or optional 8-pin SOIC
§ Operating temperature range of -40°C to

+85°C

§ Reduced performance operation down to

V

CC

= 2.5V

§ Underwriters Laboratory (UL) recognized

PIN ASSIGNMENT




















Package Dimension Information

www.maxim-ic.com/TechSupport/DallasPackInfo.htm

PIN DESCRIPTION

RST

- Reset

CLK

- Clock

DQ

- Data Input/Output

GND

- Ground

X1, X2

- Crystal Inputs

V

BAT

- + Battery Input

V

CC

- +5V

DESCRIPTION

The DS1602 is a real-time clock/elapsed time counter designed to count seconds when V

CC

power is

applied and continually count seconds under battery backup power with an additional counter regardless
of the condition of V

CC

. The continuous counter can be used to derive time of day, week, month, and year

by using a software algorithm. The V

CC

powered counter will automatically record the amount of time

that V

CC

power is applied. This function is particularly useful in determining the operational time of

equipment in which the DS1602 is used. Alternatively, this counter can also be used under software
control to record real-time eve nts. Communication to and from the DS1602 takes place via a 3-wire serial
port. A 1-byte protocol selects read/ write functions, counter clear functions and oscillator trim. A low
cost 32.768kHz crystal attaches directly to the X1 and X2 pins. If battery powered-only operation is
desired, the V

BAT

pin must be grounded and the V

CC

pin must be connected to the battery.

DS1602

8-Pin DIP (300mil)

V

CC

V

BAT

X1

X2

RST

DQ

CLK

GND

1

2

3

4

8

7

6

5

DS1602

8-Pin SOIC (208mil)

RST

DQ

CLK

GND

V

CC

V

BAT

X1

X2

1

2

3

4

8

7

6

5

DS1602

Elapsed Time Counter