3 rohs compliance, 4 operating frequency, 5 transmitter output power – Rainbow Electronics GC864-PY User Manual

Page 12: 6 reference sensitivity

Advertising
background image




Telit GE864 and GC864 Product Description

80273ST10008a Rev. 14 - 18/09/08

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 12 of 62

2.3.3

RoHS compliance


As a part of Telit corporate policy regarding environmental protection, the

GE864

and

GC864

comply

with the RoHS (Restriction of Hazardous Substances) directive of the European Union (EU Directive
2002/95/EG).

2.4 Operating Frequency


The operating frequencies in GSM, DCS, PCS modes are conform to the GSM specifications.

Mode

Freq. TX (MHz)

Freq. RX (MHz) Channels (ARFC) TX - RX offset

850

824.2ч848.8

869.2ч893.8

0 ч 124

45 MHz

890.0 - 914.8

935.0 - 959.8

0 – 124

45 MHz

E-GSM-900

880.2 - 889.8

925.2 - 934.8

975 - 1023

45 MHz

DCS-1800

1710.2 - 1784.8

1805.2 - 1879.8

512 – 885

95 MHz

PCS-1900

1850.2 - 1909.8

1930.2 - 1989.8

512 - 810

80 MHz

2.5 Transmitter output power


GSM–850/900
The

Telit GE864

and

GC864

transceiver modules in GSM–850/900 operating mode are class 4 in

accordance with the specifications which determine the nominal 2W peak RF power (+33dBm) on 50
Ohm.

DCS–1800/PCS–1900
The

Telit GE864

and

GC864

transceiver modules in DCS–1800/PCS–1900 operating mode are class 1

in accordance with the specifications which determine the nominal 1W peak RF power (+30dBm) on
50 Ohm.

2.6 Reference sensitivity


GSM–850/900
The sensitivity of the

Telit GE864

and

GC864

modules according to the specifications for the class 4

GSM 850/900 portable terminals are –107 dBm typical in normal operating conditions.

DCS–1800/PCS–1900
The sensitivity of the

Telit GE864

and

GC864

module according to the specifications for the class 1

portable terminals DCS-1800/PCS 1900 are –106 dBm typical in normal operating conditions.

Advertising