Vbot for the function of p.o.r. durning power up – Rainbow Electronics BR24L02FVM-W User Manual

Page 17

Advertising
background image

BR24L02-W / BR24L02F-W / BR24L02FJ-W /

Memory ICs

BR24L02FV-W / BR24L02FVM-W

17/25

5) Notes for power supply
V

CC

rises through the low voltage region in which internal circuit of IC and the controller are unstable, so that device

may not work properly due to an incomplete reset of internal circuit.
To prevent this, the device has the feature of P.O.R. and LV

CC

.

In the case of power up, keep the following conditions to ensure functions of P.O.R and LV

CC

.

(1) It is necessary to be “SDA=H” and “SCL=’L’ or ‘H’ ”.
(2) Follow the recommended conditions of t

R

, t

OFF

, Vbot for the function of P.O.R. durning power up.

t

R

t

OFF

Vbot

V

CC

rising wave from

V

CC

0

Recommended conditions of t

R

, t

OFF

, Vbot

Below 10ms

t

R

t

OFF

Vbot

Below 100ms

Below 0.3V

Below 0.2V

Above 10ms

Above 10ms

(3) Prevent SDA and SCL from being “Hi-Z”.
In case that condition 1. and / or 2. cannot be met, take following actions.

A) Unable to keep condition 1. (SDA is “LOW” during power up.)

Control SDA, SCL to be “HIGH” as figure below.

t

LOW

t

DH

t

SU:DAT

After V

CC

becomes stable

SDA

SCL

V

CC

a) SCL

=

"H" and SDA

=

"L"

t

SU:DAT

After V

CC

becomes stable

b) SCL

=

"L" and SDA

=

"L"

B) Unable to keep condition 2.

After power becomes stable, execute software reset. (See page14 )

C) Unable to keep condition 1 and 2.

Follow the instruction A first, then the instruction B.