Table 9. slave address decoding (add0 and add1) – Rainbow Electronics MAX1617A User Manual

Page 14

Advertising
background image

MAX1617A

Remote/Local Temperature Sensor
with SMBus Serial Interface

14

______________________________________________________________________________________

The address pin states are checked at POR and SPOR
only, and the address data stays latched to reduce qui-
escent supply current due to the bias current needed
for high-Z state detection.

The MAX1617A also responds to the SMBus Alert
Response slave address (see the

Alert Response

Address

section).

POR and UVLO

The MAX1617A has a volatile memory. To prevent ambig-
uous power-supply conditions from corrupting the data in
memory and causing erratic behavior, a POR voltage
detector monitors V

CC

and clears the memory if V

CC

falls

below 1.7V (typical, see

Electrical Characteristics

table).

When power is first applied and V

CC

rises above 1.75V

(typical), the logic blocks begin operating, although reads
and writes at V

CC

levels below 3V are not recommended.

A second V

CC

comparator, the ADC UVLO comparator,

prevents the ADC from converting until there is sufficient
headroom (V

CC

= 2.8V typical).

The SPOR software POR command can force a power-on
reset of the MAX1617A registers via the serial interface.
Use the SEND BYTE protocol with COMMAND = FCh.
This is most commonly used to reconfigure the slave
address of the MAX1617A “on the fly,” where external
hardware has forced new states at the ADD0 and ADD1
address pins prior to the software POR. The new address
takes effect less than 100µs after the SPOR transmission
stop condition.

Power-Up Defaults:

Interrupt latch is cleared.

Address select pins are sampled.

ADC begins auto-converting at a 0.25Hz rate.

Command byte is set to 00h to facilitate quick
remote Receive Byte queries.

T

HIGH

and T

LOW

registers are set to max and min

limits, respectively.

Table 8. RLTS and RRTE Temp Register Update Timing Chart

n/a (0.25Hz)

NEW CONVERSION RATE

(CHANGED VIA WRITE TO

WCRW)

Power-on reset

Auto-Convert

OPERATING MODE

CONVERSION INITIATED BY:

156ms max

TIME UNTIL RLTS AND RRTE

ARE UPDATED

156ms max

n/a

1-shot command, while idling
between automatic conversions

Auto-Convert

When current conversion is
complete (1-shot is ignored)

20sec

n/a

0.0625Hz

Rate timer

Auto-Convert

1-shot command that occurs
during a conversion

Auto-Convert

10sec

5sec

0.125Hz

0.25Hz

Rate timer

Auto-Convert

2.5sec

1.25sec

0.5Hz

1Hz

Rate timer

Auto-Convert

Rate timer

Auto-Convert

Rate timer

Auto-Convert

625ms

312.5ms

2Hz

4Hz

Rate timer

Auto-Convert

237.5ms

156ms

8Hz

n/a

STBY pin

Hardware Standby

Rate timer

Auto-Convert

Rate timer

Auto-Convert

156ms

156ms

n/a

n/a

1-shot command

Software Standby

RUN/STOP bit

Software Standby

Table 9. Slave Address Decoding (ADD0
and ADD1)

Note: High-Z means that the pin is left unconnected and floating.

0011 001

High-Z

GND

0011 000

ADDRESS

0101 001

GND

High-Z

0011 010

V

CC

GND

0101 011

V

CC

High-Z

0101 010

1001 101

High-Z

V

CC

1001 100

GND

GND

GND

V

CC

High-Z

High-Z

1001 110

V

CC

V

CC

ADD0

ADD1

Advertising