Slave Addresses

The MAX1669 appears to the SMBus as one device
having a common address for the temperature sensor
section, GPIO section, and fan-control section. The
device address can be set to one of eight different val-
ues by pin-strapping ADD_ pins so that more than one
MAX1669 can reside on the same bus without address
conflicts (Table 11).

The MAX1669 also responds to the SMBus Alert
Response slave address (see the Alert Response
Address
section).

POR and UVLO

The MAX1669’s memory is volatile. To prevent ambigu-
ous power-supply conditions from corrupting the data
in memory and causing erratic behavior, a POR voltage
detector monitors V

CC

and clears the memory if V

CC

falls below 1.85V (typical, see the Electrical Character-
istics
table). When power is first applied and V

CC

rises

above 1.9V (typ), the logic blocks begin operating;
although reads and writes at V

CC

levels below 3V are

not recommended. A second V

CC

comparator, the

ADC UVLO comparator, prevents the ADC from con-
verting until there is sufficient headroom (V

CC

= 2.8V typ).

MAX1669

Fan Controller and Remote Temperature Sensor

with SMBus Serial Interface

______________________________________________________________________________________

15

4

TRAN2*

This bit is set if a low-to-high or high-to-low transition has occurred at I/O2 (regardless of the
state of the mask bits).

3

RHIGH*

A high indicates that the high-temperature alarm has activated

This bit is set if a low-to-high or high-to-low transition has occurred at I/O1 (regardless of the
state of the mask bits).

TRAN1*

5

BIT

This bit indicates the current state of I/O2 (unlatched).

I/O2

6

This bit indicates the current state of I/O1 (unlatched).

I/O1

7

(MSB)

FUNCTION

NAME

1

DIODE

A high indicates a remote-diode fault (open-circuit, shorted diode, or DXP short to GND).

0 (LSB)

OVERT

When the T

CRIT

threshold is crossed, this bit goes high. The polarity of this bit does not depend

on the POL bit (bit 5 in configuration byte).

A high indicates that the low-temperature alarm has activated.

RLOW*

2

Table 9. Status Byte Bit Assignments

*TRAN1 and TRAN2 alarm flags stay high until cleared by POR or until the status byte register is read. RHIGH and RLOW alarm

flags stay high until cleared by POR or the temperature fault is removed and the status byte is read.

0000 0000

0000 0101

MS BYTE

LSBs MSBs

LS BYTE

LSBs MSBs

MAX1669 ID CODE

Table 10. Device ID Code

Table 11. Slave Address Decoding
(ADD_ Pins)

ADD0

V

CC

GND

GND

GND

GND

GND

ADD1

ADD2

ADDRESS

0011 001b

0011 000b

GND

V

CC

GND

0011 010b

GND

V

CC

V

CC

0101 001b

V

CC

GND

GND

0101 010b

V

CC

GND

V

CC

0101 011b

V

CC

V

CC

GND

1001 100b

V

CC

V

CC

V

CC

1001 101b