Typical operating characteristics (continued), Pin description – Rainbow Electronics MAX1669 User Manual

Page 6

Advertising
background image

MAX1669

Fan Controller and Remote Temperature Sensor
with SMBus Serial Interface

6

_______________________________________________________________________________________

Typical Operating Characteristics (continued)

(Temperature error = measured - actual, T

A

= +25°C, unless otherwise noted.)

Pin Description

0

20

40

60

80

100

0

4

2

5

7 8

10

12

3

1

6

9

11

13 14 15

PWM DUTY FACTOR vs. CODE (D3D2D1D0)

MAX1669-09

CODE (D3D2D1D0)

DUTY FACTOR (%)

V

CC

= +3.3V OR +5V

0

0.5

1.5

1.0

2.0

3.5

3.0

2.5

4.0

4.5

5.0

0

4

2

5

7 8

10

12

3

1

6

9

11

14

13

15

DAC OUTPUT vs. CODE (D3D2D1D0)

MAX1669-10

CODE (D3D2D1D0)

DAC OUTPUT (V)

I

LOAD

= +10mA TO -10mA

V

CC

= +5V

NAME

FUNCTION

1

I/O1

General-Purpose Open-Drain Logic Input/Output 1. I/O1 is intended for driving LEDs, driving power-plane
switching MOSFETs, or detecting fan presence or chassis intrusion.

2

I/O2

General-Purpose Open-Drain Logic Input/Output 2. I/O2 is intended for driving LEDs, driving power-plane
switching MOSFETs, or detecting fan presence or chassis intrusion.

PIN

3

ADD0

SMBus Address Select Pin 0. See Table 11.

4

ADD1

SMBus Address Select Pin 1. See Table 11.

8

DXP

Combined Current Source and ADC Positive Input from Remote Diode. Place a 2200pF capacitor
between DXP and DXN for noise filtering.

7

DXN

Combined Current Sink and ADC Negative Input from Remote Diode. DXN is normally biased to a diode
voltage above ground.

6

AGND

Analog Ground

5

ADD2

SMBus Address Select Pin 2. See Table 11.

13

SMBCLK

SMBus Serial-Clock Input

12

PGND

Power Ground

11

FAN

Fan-Control Logic Output. Swings from PGND to V

CC

in PWM mode, or PGND to 0.94 · V

CC

in DAC mode.

10

SYNC

Oscillator Synchronization Input. Connect to AGND to use internal clock. Capture range is 140kHz to
400kHz. The synchronization signal is internally applied to the FAN PWM clock. See Table 5 for synchro-
nized frequencies.

9

V

CC

Supply Voltage Input, +3V to +5.5V. Bypass to AGND with a 0.1µF capacitor.

16

OVERT

Active-Low, Open-Drain Thermostat Output. Activated by T

CRIT

threshold

15

ALERT

Active-Low, Open-Drain SMBus Alert (interrupt) Output

14

SMBDATA

Open-Drain SMBus Serial-Data Input/Output

Advertising