-13-

Panel Lock

Sliding this switch to the right will disable all of the controls on the BodyBeat Sync to prevent the

accidental alteration of any settings during use. A “locked” icon will be revealed on the switch as well as on

the LCD display. Sliding the switch back to the left will reveal an “unlocked” icon and will re-enable the

controls for use. When locked, the “locked” icon will flash when any button is pressed to remind the user

that the panel has been locked.

The Panel Lock switch does not disable the ability to power the unit on or off or to adjust the

volume. Powering the unit off does, however, require the use of the Shift Key to avoid accidentally

turning the unit off during normal operation. See Start/Stop On/Off.

Start / Stop - On

/ Off

Starts and Stops the Metronome both in normal Metronome Preset mode and in MIDI Tempo Map

Playback mode. When the unit is off, pressing and holding this button for 2 seconds will power the unit

on.

SHIFT FUNCTION: - When the unit is on, pressing and holding this button for 2 seconds while

holding the Shift button will power the unit off.

Note: The BodyBeat Sync can start in different modes of operation by holding other buttons

while powering on. See sections entitled “POWER ON FUNCTION” in Sync Mode Select and

Tempo Select.