Peerless-AV RMI1 - Installation User Manual

Page 2

Advertising
background image

2 of 4

ISSUED: 06-16-08 SHEET #: 120-9049-1

Visit the Peerless Web Site at www.peerlessmounts.com

For customer care call 1-800-865-2112 or 708-865-8870.

If necessary, disengage T-handle from sprocket
plate of rotational mount (A) and rotate sprocket
so largest hole pattern aligns with clearance
holes of sprocket.

Align inner most M10 hole set and fasten
rotational mount assembly (A) to PLP adapter
plate with four M10 x 15 mm screws (B) as
shown. Tighten all fasteners with 6 mm allen
wrench (F).

NOTE: Be sure outer flange of PLP adapter plate
face away from rotational mount.

NOTE: Skip step 2 if dedicated PLP adapter
plate is already attached to screen.

1

Place PLP adapter plate on back of screen,
align to holes, and center on back of screen.
Secure PLP adapter plate to back of screen
using fasteners provided with PLP adapter plate.

2

DEDICATED PLP
ADAPTER PLATE

Attaching Rotational Mount to PLP Model Adapter Plate

NOTE: Dedicated PLP model adapter plate not included. For screen compatibility please call customer care to
purchase a dedicated PLP adapter plate.

FLANGE

B

DEDICATED PLP
ADAPTER PLATE

T-HANDLE

A

Advertising