English Manual: Compact Retract 12/24V, Version 2

14/04/2005

Please note that panels are only fully waterproof from the front, if installed correctly. However

the area behind the dashboard should be kept dry to avoid the risk of oxidation of the cable

connecter contacts.

For full installation instructions of the control panels please refer to “Installation Guidelines “ as

supplied with each control panel.

4.3 CONTROL

SYSTEM

For the wiring of the electronic control card and the control system, please refer to the diagrams

Compact Retract, 12/24: Electronic Control Box Connections

” and “

Compact Retract12/24V:

Control Wiring

” page 20.

Install the thruster control box as close as possible to the thruster unit and thruster relay box in a
dry area above the waterline.

All wires should be carefully labelled to reduce the chance of error and simplify checking and
troubleshooting. Try to use the colour scheme as used on the control wiring diagram in order to

facilitate future maintenance and troubleshooting.

All wire ends for terminals should be tinned before crimping or inserting into terminal blocks.
The wire dimensions should be of the specified dimensions.

Install a double pole breaker/isolator in the supply wiring of the thruster control box on the

boats’ main electrical switchboard marked BOW THRUSTER: Please keep in mind voltage drop in
cable run from control box to main electrical switch board.

This breaker/isolator should ideally be supplied from an independent battery bank, to the one
used for powering the thruster unit.

The installer must protect the positive supply cable of the thruster control box by means of a fuse

(8 A) as indicated in the above mentioned diagrams. The size of the supply wires (red & black)
depends on the length of the cable run, the voltage drop in these cables should not exceed 5%

of the nominal battery voltage.

For safety reasons and in order to benefit from all the functions provided by the thruster’s
electronic controller, an electric battery isolator needs to be installed in the thruster motor’s

positive supply cable.

It is important to isolate the thruster motor power circuit by means of a battery

isolator(manual/electric) after having left port & when the manoeuvre is finished, after docking.

Please Note: All wiring must be insulated from ground and should be installed in compliance
with acceptable standards that require all junctions to be in waterproof boxes equipped with

glands. All wiring should be kept outside of bilge’s and other habitually wet areas.

11