MAX Power VIP250-HYD User Manual

Page 12

Advertising
background image

VIP 250, Hydraulic with Electronic Controller

25/12/2005

12


For large diameter cables it may be easier to use two smaller cables instead (in order to allow

for a greater flexibility of movement). For example: 2 x 50 mm² instead of 95 mm². Cables at

thruster unit should be free to move, without kinking when VIP goes up and down

+

_

Power Relay

24V
High Power Starting
Type Battery Bank

Fuse

Electric Motor

Hydrualic
Pump

Electric/Manual
Battery Isolater

From Oil Resevoir

To Directional Control Valve

5.3 POWER

FUSE:

Sizing of fuses for overcurrent protection are a function of the cable sizes in the circuit,
not the amperage drawn by the appliance (electropump motor) in the circuit. It is thus

not the electropump motor that is protected by the fuse, but the power cables supplying

the thruster motor.

Fuse

Fuse
Holder

VIP 150 Hydraulic

Max Power Fuse Size

315 A

Regular Fuse Rating

600 A

Max Power Part Number

for fuse.

OPTI 3121

Max Power Part Number

for fuse holder.

OPTI 3091

The Max Power fuse has been application selected for it’s
time and current characteristics, consequently a much

lower rated fuse than traditionally rated may be fitted.

Max Power recommends the following fuses and fuse

holders as supplied by Max Power:

Advertising