MAX Power VIP250-HYD User Manual

Page 13

Advertising
background image

VIP 250, Hydraulic with Electronic Controller

25/12/2005

13





OR

VIP 250 Hydraulic with 24V Electropump

-

+

-

+

12 V
800 CCA
50 Ah

12 V
800 CCA
50 Ah

-

+

-

+

12 V
800 CCA
50 Ah

12 V
800 CCA
50 Ah

To 24 V Electropump
Series/Parallel

Pos. ( + )

Neg. ( - )

Minimum Battery
Bank Size

-

+

-

+

12 V
800 CCA
50 Ah

12 V
800 CCA
50 Ah

24 V
2400 CCA
150 Ah
Series/Parallel

Pos. ( + )

-

+

12 V
800 CCA
50 Ah

Neg. ( - )

-

+

-

+

12 V
800 CCA
50 Ah

12 V
800 CCA
50 Ah

-

+

12 V
800 CCA
50 Ah

Ideal Battery
Bank Size

If the dedicated batteries are charged by the alternator, the reference of the charge must be

taken after the diode-splitting block (if in doubt, consult a marine electrician).

If the batteries or cables are inferior to those recommended, the VIP will not reach its

potential thrust. The greater the batteries and cables size, the better the thrust.

Do not ground the VIP.

5.5 BATTERY

ISOLATOR:

A manual battery isolator, of the correct size, should be installed in the positive supply cable,

as close as possible to the thruster battery bank and should be easily accessible and clearly

marked.

An electrical battery isolator, as supplied by Max Power, should also be installed in the

positive supply cable, as close as possible to the thruster battery bank, in order to benefit from
all automatic safety features of the electronic control system.

VIP 250 Hydraulic 24V

Type of Batteries

Exide, Maxxima 900

Number of Batteries

4 to 6

Type of Connection

Series/Parallel

5.4 ELECTROPUMP BATTERY REQUIREMENTS :

When choosing the type of batteries needed for your thruster’s battery bank, keep in mind

that it is the CCA (Cold Cranking Amps) capacity that is the most important and not the Ah
(Amp-hour) capacity. This is because thrusters draw high currents, but only for very short

periods of time (maximum 3 min.)

Advertising